ANALISIS PENURUNAN BEDA TEKANAN DI POMPA PENDINGIN SEKUNDER REAKTOR GA SIWABESSY

Murjati, Bambang and Royadi, Royadi and Amril, Amril (2016) ANALISIS PENURUNAN BEDA TEKANAN DI POMPA PENDINGIN SEKUNDER REAKTOR GA SIWABESSY. Prosiding Seminar Nasional Teknologi dan Aplikasi Reaktor Nuklir. ISSN 976-602-6423-00-9

[thumbnail of 10_bambang M-1.pdf]
Preview
Text
10_bambang M-1.pdf

Download (386kB) | Preview

Abstract

ANALISIS PENURUNAN BEDA TEKANAN DI POMPA PENDINGIN SEKUNDER REAKTOR GA SIWABESSY. Sistem pendingin sekunder RSG-GAS berfungsi untuk memindahkan panas yang dibangkitkan reaktor ke lingkungan. Sistem pendingin ini dilengkapi dengan pompa untuk mensirkulasikan air pendingin dan alat kontrol tekanan. Setiap pompa pendingin sekunder pada saat operasi, tekanan pada bagian sisi isapnya akan menunjuk pada batas aman antara 0,18 s/d 0,13 bar dan dinyatakan kritis pada angka 0,11bar untuk menghindari kapitasi yang dapat menyebabkan kerusakan. Oleh karena itu ketika tekanan mencapai nilai minimum 0,10bar, alat kontrol tekanan akan mematikan pompa secara otomatis. Makalah ini membahas penyebab turunnya tekanan. Dari hasil analisis disimpulkan bahwa pressure drop di pompa pendingin sekunder akibat kotoran yang tersangkut di filter mekanik.
Kata kunci: pendingin sekunder, ram filter mekanik, solusi.
ABSTRACT.
ANALYSIS OF DIFFERENT PRESSURE DECREASE IN SECONDARY PUMP COOLING REACTOR GA SIWABESSY. Secondary cooling system RSG-GAS serves to remove heat generated reactors into the environment. The cooling system is equipped with a pump to circulate cooling water and pressure control equipment. Each secondary cooling pump at the time of surgery, the pressure at the suction side will point to safe limits between 0.18 s / d 0.13 bar and declared critical on 0,11bar to avoid capitation rate which can cause damage. Therefore when the pressure reaches a minimum value 0,10bar, pressure control device will shut off the pump automatically. This paper discusses the cause of the drop in pressure. From the analysis it is concluded that the pressure drop in the secondary coolant pumps due to dirt caught in the mechanical filters.
Keywords: secondary cooling, ram mechanical filters, solutions.

Item Type: Article
Subjects: Taksonomi BATAN > Reaktor Nuklir > Teknologi Reaktor > Sistem Reaktor
Taksonomi BATAN > Reaktor Nuklir > Teknologi Reaktor > Sistem Reaktor
Divisions: BATAN > Pusat Reaktor Serba Guna
IPTEK > BATAN > Pusat Reaktor Serba Guna
Depositing User: Administrator Repository
Date Deposited: 30 Oct 2018 02:38
Last Modified: 31 May 2022 04:45
URI: https://karya.brin.go.id/id/eprint/4176

Actions (login required)

View Item
View Item