Validasi Kit IRMA TSH untuk Penentuan Kadar TSH Dalam Serum Darah Manusia

Mondrida, Gina and Sutari, Sutari and Triningsih, Triningsih and Setiyowati, Sri and Susilo, V. Yulianti and Lestari, Wening and Ariyanto, Agus and Widayati, Puji (2018) Validasi Kit IRMA TSH untuk Penentuan Kadar TSH Dalam Serum Darah Manusia. Jurnal Kimia dan Pendidikan Kimia, 3 (3). pp. 126-134. ISSN 2503-4154

[thumbnail of Validasi Kit IRMA TSH untuk Penentuan Kadar TSH Dalam Serum Darah Manusia] Text (Validasi Kit IRMA TSH untuk Penentuan Kadar TSH Dalam Serum Darah Manusia)
1986 - Published Version
Available under License Creative Commons Attribution Non-commercial Share Alike.

Download (61kB)

Abstract

TSH IRMA kit is a kit used for the determination of TSH (Thyroid Stimulating Hormone) levels in human blood serum. Thyroid hormone is a hormone that our bodies need for growth of the brain, bone and other tissues and regulate the metabolism in the body. TSH normal range for adult is in the range of 0.4-4.5 mIU/L, whereas for baby is about 3.0-18.0 mIU/L. Thyroid would affect the quality of optimal growth of children if disturbed. Therefore, TSH assay in the blood needs to be determined to know whether the function of the thyroid gland works normally or not. Detection of TSH in blood can be performed by Immunoradiometricassay (IRMA) method. IRMA method is one of the immunoassay techniques based on immunological reactions (antigen-antibody binding) using radionuclide 125I as a tracer, that sample in small quantity can be detected. IRMA method was developed locally by replacing TSH IRMA kit which is costly since imported from commercial companies. Center for Radioisotope and Radiopharmaceutical Technology (PTRR) BATAN has successfully developed the TSH IRMA kit that can be used to determine the levels of TSH in human blood. TSH IRMA kit must be validated to know the limit of detection, sensitivity, accuracy, precision and the assay parameters, such as Non-Specific Binding (NSB) and Maximum Binding (MB). Validation of TSH IRMA kit had been carried out resulting in the limit of detection of 0.115 ng/mL, accuracy with a recovery of 93.6-108.0 %, intra-assay precision (% CV) QC L = 1.9848, QC M = 3.6360 % and QC H = 2.2085 % while the inter-assay precision (% CV) QC L = 11.0055, QC M = 5.6768 % and QC H = 5.4181 %. It was concluded that this TSH IRMA kit showed good performance based on the % NSB and % B/T of 0.68 and 34.64 %, respectively.

Item Type: Article
Subjects: Taksonomi BATAN > Isotop dan Radiasi > Produksi Isotop dan Sumber Radiasi > Teknik Produksi Radiofarmaka
Divisions: BATAN > Pusat Teknologi Radioisotop dan Radiofarmaka
IPTEK > BATAN > Pusat Teknologi Radioisotop dan Radiofarmaka
Depositing User: Administrator Repository
Date Deposited: 22 Jun 2019 15:22
Last Modified: 02 Jun 2022 03:16
URI: https://karya.brin.go.id/id/eprint/9083

Actions (login required)

View Item
View Item