PERANCANGAN SENSOR PENGUKUR KECEPATAN KAPSUL IRADIASI DI FASILITAS SISTEM RABBIT PNEUMATIK

Ali, Hanapi and Mustofa, Kawkab and Sunarko, Sunarko and Sufmawan, Asnul (2018) PERANCANGAN SENSOR PENGUKUR KECEPATAN KAPSUL IRADIASI DI FASILITAS SISTEM RABBIT PNEUMATIK. Buletin "Reaktor". ISSN ISSN: 0216-2695

[thumbnail of HANAFI ALI.pdf]
Preview
Text
HANAFI ALI.pdf

Download (903kB) | Preview

Abstract

PERANCANGAN SENSOR PENGUKUR KECEPATAN KAPSUL IRADIASI PNEUMATIK DI FASILITAS RABBIT SISTEM PNEUMATIK. Fasilitas iradiasi rabbit sistem pneumatik dikhususkan untuk mengiradiasi suatu spesimen atau sampel dengan waktu paruh pendek, sehingga dibutuhkan waktu transfer yang singkat dengan kecepatan transfer yang disyaratkan sebesar 10 m/s. Mengetahui kecepatan transfer kapsul bermanfaat dalam menentukan waktu iradiasi dan proteksi terhadap rusaknya kapsul tersebut karena tumbukan. Penelitian ini bertujuan untuk mengetahui perkiraan keakuratan sensor pengukur kecepatan yang dirancang. Dua buah sensor berbasis fotoelektrik digunakan untuk mengukur waktu layang atau Time of Flight (ToF) yang dibangkitkan oleh media yang diukur. Percobaan dilakukan menggunakan simulasi digital dengan perangkat lunak. Hasil percobaan menunjukkan hubungan antara waktu layang terhadap error pengukuran dan error kecepatan 10 m/s sebesar 2%. Error 2 % didapatkan dari hasil pengolahan data secara statistik.
Kata Kunci : Rabbit sistem pneumatik, perancangan sensor kecepatan, waktu layang, foto elektrik, iradiasi
ABSTRACT

DESIGN OF PNEUMATIC IRRADIATION CAPSULES SPEED SENSORS IN PNEUMATIC SYSTEM RABBIT FACILITIES. Pneumatic system rabbit irradiation facility is specialized to irradiate a specimen or sample with a short half-life, therefore a short transfer time is required with the required transfer speed of 10m/s. Knowing the transfer rate of the capsule is useful to determine the irradiation time and protection against any damage to the capsule due to collisions. This study aims to determine the approximate accuracy of the designed speed measuring sensor. Two photoelectric based sensors are used to measure the Time of Flight (ToF) generated by the measured media. Experiments were carried out using digital simulations with software. The result of the experiments show the relationship between Time of flight (Tof) to the measurement error and error at a speed of 10 m / s by 2%. A 2% error is obtained from the results of statistical data processing.

Keywords: Rabbit pneumatic system, speed sensor design, Time of flight (ToF), photo electric, irradiation

Item Type: Article
Subjects: Taksonomi BATAN > Reaktor Nuklir > Pemanfaatan Reaktor > Iradiasi Target
Taksonomi BATAN > Reaktor Nuklir > Pemanfaatan Reaktor > Iradiasi Target
Divisions: BATAN > Pusat Reaktor Serba Guna
IPTEK > BATAN > Pusat Reaktor Serba Guna
Depositing User: Administrator Repository
Date Deposited: 29 Jan 2019 03:34
Last Modified: 02 Jun 2022 03:15
URI: https://karya.brin.go.id/id/eprint/8479