Basuki, Prasetyo and KA, Sudjatmi (2009) SISTEM PEMANTAUAN RADIOAKTIVITAS AIR TANGKI REAKTOR TRIGA 2000 DENGAN SPEKTROMETER GAMMA ON-LINE. In: Seminar Nasional Sains dan Teknologi Nuklir 2009, 3 Juni 2009, Bandung, Indonesia.
Semnas Sains dan Teknologi Nuklir2009.pdf
Download (114kB) | Preview
Prasetyo Basuki_Semnas_2009_ Sistem Pemantauan Radioaktivitas Air Tangki Reaktor Triga 2000 Dengan Spektrometer Gamma On-Line.pdf
Download (186kB) | Preview
Abstract
SISTEM PEMANTAUAN RADIOAKTIVITAS AIR TANGKI REAKTOR TRIGA 2000 DENGAN SPEKTROMETER GAMMA ON-LINE. Salah satu persyaratan dalam keselamatan radiasi pada beroperasinya sebuah reaktor penelitian adalah tidak adanya lepasan radionuklida hasil fisi ke air pendingin reaktor dan udara lingkungan. Deteksi dini terhadap lepasan radionuklida hasil fisi dari elemen bakar ke air pendingin dapat dilakukan dengan pemeriksaan radioaktivitas air pendingin primer. Air tangki reaktor dapat menjadi indikator penting dalam mendeteksi kadar radioaktivitas dari material hasil fisi, apabila terjadi kebocoran pada kelongsong elemen bakar. Untuk itu diperlukan sistem pengujian yang dapat mengukur tingkat radioaktivitas air ini secara langsung dan sederhana. Ide dari sistem pengujian secara langsung ini adalah dengan melewatkan aliran air tangki langsung pada detektor gamma yang terpasang di spektrometer gamma. Air tangki reaktor dialirkan pada suatu slang plastik menuju kotak marinelli yang terpasang tepat diatas detektor gamma. Posisi tangki yang lebih tinggi dari kotak marinelli memungkinkan air mengalir secara gravitasi dengan laju volume 5,1 liter/menit. Laju volume keluaran lebih kecil sebesar 2,2 liter/menit. ;
RADIOACTIVITY MONITORING SYSTEM FOR TRIGA 2000 REACTOR WATER TANK WITH ON-LINE GAMMA SPECTROMETER. One of the requirements in radiological safety in the operating condition of research reactor are the absence of radionuclide from fission product released to reactor cooling water and environment. Early detection of fission product that released from fuel element can be done by monitoring radioactivity level on primary cooling water.Reactor cooling water can be used as an important indicator in detecting radioactivity level of material fission product, when the leakage occurs. Therefore, it needs to build a monitoring system for measuring radioactivity level of cooling water directly and simple. The idea of this system is counting radioactivity water flow from reactor tank to the marinelli cube that attached to the HPGe detector on gamma spectrometer. Cooling water from tank aimed on plastic pipe to the marinelli cube. Water flows in gravitational driven to the marinelli cube, with volume flow rate 5.1 liters/minute in the inlet and 2.2 liters/minute in output.
Item Type: | Conference or Workshop Item (Paper) |
---|---|
Uncontrolled Keywords: | Kata kunci : reaktor penelitian, hasil fisi, gravitasi, laju volume, spektrometer gamma |
Subjects: | Taksonomi BATAN > Reaktor Nuklir Taksonomi BATAN > Reaktor Nuklir Taksonomi BATAN > Reaktor Nuklir > Operasi dan Pemeliharaan Reaktor > Operasi Taksonomi BATAN > Reaktor Nuklir > Operasi dan Pemeliharaan Reaktor > Operasi Taksonomi BATAN > Reaktor Nuklir > Teknologi Reaktor > Fisika Reaktor Taksonomi BATAN > Reaktor Nuklir > Teknologi Reaktor > Fisika Reaktor Taksonomi BATAN > Reaktor Nuklir > Teknologi Reaktor > Sistem Reaktor Taksonomi BATAN > Reaktor Nuklir > Teknologi Reaktor > Sistem Reaktor |
Divisions: | BATAN > Pusat Sains dan Teknologi Nuklir Terapan IPTEK > BATAN > Pusat Sains dan Teknologi Nuklir Terapan |