Diyah Erlina Lestari, DEL and Setyo Budi Utomo, SBU and Harsono, Harsono and Amril, Amril (2013) EVALUASI PENGOPERASIAN SISTEM INJEKSI BAHAN KIMIA PENGENDALI PH (PAQ03) PADA SISTEM PENDINGIN SEKUNDER REAKTOR RSG-GAS. PROSIDING SEMINAR NASIONAL TEKNOLOGI DAN APLIKASI REAKTOR NUKLIR. ISSN 978-979-17109-8-5
26_DIYAH ERLINa.pdf
Download (518kB) | Preview
Abstract
EVALUASI PENGOPERASIAN SISTEM INJEKSI BAHAN KIMIA PENGENDALI pH (PAQ03) PADA SISTEM PENDINGIN SEKUNDER REAKTOR RSG-GAS. Sistem injeksi bahan kimia pengendali pH(PAQ03 ) merupakan salah satu sistem pengendali kualitas air pendingin sekunder yang berfungsi untuk mengendalikan pH pada sistem pendingin sekunder. Sebagai bahan kimia pengendali pH yang digunakan adalah larutan asam sulfat (H2SO4) 10 % yang dalam penginjeksiannya menggunakan dua pompa dan dioperasikan secara manual kontinyu pada saat sistem pendingin sekunder beroperasi. Telah dilakukan evaluasi pengoperasian sistem injeksi bahan kimia pengendali pH(PAQ03 ). Evaluasi dilakukan dengan mengamati kebutuhan bahan kimia , laju injeksi bahan kimia dengan perubahan pH yang terjadi pada air pendingin sekunder dalam kondisi air pendingin sebelum dan sesudah dilakukan pembersihan kolam pendingin sekunder. Dari pengamatan menunjukan bahwa pengoperasikan injeksi bahan kimia pengendali pH(PAQ03 ) secara manual kontinyu belum dapat menurunkan pH air pendingin sekunder , tergantung pada kualitas air pasokan dan perlakuan pengendalian kualitas air lainnya tetapi dapat mempertahankan pH air pendingin sekunder pada batasan yang diizinkan yaitu dibawah 8.
ABSTRACT
EVALUATION OPERATION OF INJECTION CHEMICAL pH CONTROL SYSTEM ( PAQ03 ) ON SECONDARY COOLING SYSTEM RSG - GAS REACTOR .The injection chemical pH control system ( PAQ03 ) is one of the quality control system of secondary cooling water which is used to control the pH in the secondary cooling system . As pH control chemicals used is a solution of sulfuric acid ( H2SO4 ) 10 % are in injected by using two pumps and manually operated continuously during pH secondary cooling system operates . The evaluation operation of the injection chemical control system ( PAQ03 ) has been performed. Evaluation is done by observing the needs of chemicals , chemical injection rate with pH changes that occur in the secondary cooling water in the cooling water conditions before and after cleaning the secondary cooling pond . From the observations show that the operation of injection chemicals pH system ( PAQ03 ) manually continuously, can not lowering the pH secondary cooling water, depending on the quality of water supply and other water treatment quality control but can maintain the pH secondary cooling water to the extent that is permitted under 8.
Item Type: | Article |
---|---|
Subjects: | Taksonomi BATAN > Reaktor Nuklir > Perencanaan Sistem Energi Nuklir Taksonomi BATAN > Reaktor Nuklir > Perencanaan Sistem Energi Nuklir |
Divisions: | BATAN > Pusat Reaktor Serba Guna IPTEK > BATAN > Pusat Reaktor Serba Guna |
Depositing User: | Administrator Repository |
Date Deposited: | 30 Oct 2018 07:32 |
Last Modified: | 31 May 2022 09:13 |
URI: | https://karya.brin.go.id/id/eprint/4206 |