EVALUASI PENAIKAN DAYA MENUJU 15 MW SIKLUS TERAS 83 REAKTOR GA SIWABESSY

Sriawan, Sriawan and Purwadi, Purwadi (2013) EVALUASI PENAIKAN DAYA MENUJU 15 MW SIKLUS TERAS 83 REAKTOR GA SIWABESSY. PROSIDING SEMINAR NASIONAL TEKNOLOGI DAN APLIKASI REAKTOR NUKLIR. ISSN 978-979-17109-8-5

[thumbnail of 22_SRIAWAN TBR.pdf]
Preview
Text
22_SRIAWAN TBR.pdf

Download (654kB) | Preview

Abstract

EVALUASI PENAIKAN DAYA MENUJU 15 MW SIKLUS TERAS 83 REAKTOR GA SIWABESSY. Telah dilakukan evaluasi unjuk kerja kanal-kanal pengukur daya reaktor pada penaikan daya menuju 15 MW siklus ke 83 operasi Reaktor Serba Guna GA. Siwabessy (RSG-GAS). Pengamatan dilakukan untuk mengetahui apakah unjuk kerja kanal-kanal tersebut tidak menyimpang dari yang dipersyaratkan sehingga daya reaktor dapat dinaikkan.. Kanal-kanal pengukur daya yang diamati antara lain adalah kanal jangkauan start-up, kanal jangkauan menengah, dan kanal jangkauan daya. Selain pengamatan kanal-kanal tersebut, dilakukan juga pengamatan indikator posisi batang kendali dan pengamatan instrumen lainnya yang berkaitan dengan pengoperasian reaktor. Dari hasil evaluasi unjuk kerja kanal pengukur daya diketahui bahwa semua kanal pengukur daya bekerja dalam lingkup yang diharapkan yaitu penunjukan kanal start-up < 1 x 105cps, kanal jangkauan menengah > 1 x 10-7 A dan kanal jangkauan daya , 109% daya nominal. Ini berarti bahwa tidak ada penyimpangan dari batas-batas operasi. Disimpulkan bahwa penaikan daya menuju 15 MW dapat dilaksanakan dengan selamat dan aman.
Kata kunci: unjuk kerja, kanal pengukur daya, RSG-GAS
ABSTRACT
EVALUATION ON POWER ACCESSION TO 15 MW OF THE EIGHTY-THREE CORE CYCLES OF GA. SIWABESSY REACTOR . It has been evaluated the performance of canals measuring power during power accession to 15 MW to the eighty-three core cycles of the GA Siwabessy Reactor (RSG-GAS). Aim of this measure is to acknowledge whether those systems are still function properly. The canals measuring power observed including power meters start-up channel range, intermediate-range channels, and channel power range. Besides that, measures were also conducted such as observations of control rod position indicators and observation of other instruments associate to the reactor operation. Evaluation result shown that all canals measuring power are well function. They are covering start-up channel range of < 1 x 105cps, intermediate-range channels of > 1 x 10-7 and channel power range of 109% of nominal power. It can be concluded that power accesion to 15 MW is safely be accomplisehed.
Key words: performance, canal measuring power, RSG-GAS.

Item Type: Article
Subjects: Taksonomi BATAN > Reaktor Nuklir > Operasi dan Pemeliharaan Reaktor > Operasi
Taksonomi BATAN > Reaktor Nuklir > Operasi dan Pemeliharaan Reaktor > Operasi
Divisions: BATAN > Pusat Reaktor Serba Guna
IPTEK > BATAN > Pusat Reaktor Serba Guna
Depositing User: Administrator Repository
Date Deposited: 30 Oct 2018 07:27
Last Modified: 31 May 2022 09:15
URI: https://karya.brin.go.id/id/eprint/4203