Nugroho Luhur, NL and Subiharto, Subiharto (2016) EVALUASI UNJUK KERJA MEMORI SISTEM SPEKTROMETER GAMMA. Prosiding Seminar Nasional Teknologi dan Aplikasi Reaktor Nuklir. ISSN 976-602-6423-00-9
17-NUGROHO FIX (1).pdf
Download (573kB) | Preview
Abstract
EVALUASI UNJUK KERJA MEMORI SISTEM SPEKTROMETER GAMMA. Sistem spektroskopi gamma merupakan sistem pencacah radiasi yang paling banyak digunakan dalam berbagai pengukuran. Pada spektrometer terdapat instrumen analog to digital converter (ADC) yang digunakan untuk menkonversi sinyal analog (amplitudo pulsa) menjadi nilai digital yang sesuai kemudian dikonversikan ke dalam nomor kanal dan jumlah sinyal yang di cacah disimpan dalam memori pada spektrometer. Tulisan ini bertujuan untuk mengevaluasi unjuk kerja memori sistem spektrometer gamma milik Bidang Keselamatan Kerja dan Operasi (BK2O). Jumlah radiasi yang disimpan oleh memori spektrometer perlu dilakukan pengujian ketidaklineran atau disebut Diferrensial Non Linieryty (DNL).. Metode pengujian yaitu dengan dengan menggantikan pulsa dari detektor dengan sumber pulsa yang dapat memberikan input dengan amplitudo pulsa yang berbeda-beda mulai dari yang terkecil sampai 10 Volt. Diperoleh hasil pengujian DNL spektrometer gamma sebesar 1,17 %. Hasil ini masih mendekati spsifikasi DNL spektrometer yaitu sebesar 1 %. Disimpulkan bahwa sistem spektrometer gamma ADC-MCA model TRUMP PCI 16K buatan Canberra mempunyai Nilai DNL (Diffrensial Non Linearity) sebesar 1,17 %. NIlai tersebut masih mendekati nilai referensi DNL dari spectrometer
Kata kunci: memori, spektrometer,MCA
ABSTRACT
EVALIATION OF MEMORY PERFORMANCE OF SPECTROMETER GAMMA SYSTEM. Gamma spectroscopy system is a system of radiation counting mostly used in a variety of measurements. In spectrometer there is an instrument memory the analog to digital converter (ADC) used to convert the analog signal (pulse amplitude) into the appropriate digital value that is then converted into the channel number. This paper is aimed to evaluate the memory performance of spectrometer gamma system owned BK2O. The amount of radiation deposited by the spectrometer is necessary to unlinerrity test called Diferrensial Non Linieryty (DNL).. Testing methods is done by replacing pulses of the detector with a pulse source that can provide input to the pulse amplitude by varying value from the smallest up to 10 Volts. It is obtained that DNL mtest result of gamma spectrometer is 1.17 %. This results are still approaching DNL in spsifikasi of 1%. It is concluded that gamma spectrometer system of AND-MCA model TRIUM PCI 16K made by CANBERRA having value of DNL of 17%. This value is still approaced than that of DNL reference of spectrometer
Keywords: memori, spektrometer, MCA
Item Type: | Article |
---|---|
Subjects: | Taksonomi BATAN > Reaktor Nuklir > Teknologi Reaktor > Sistem Reaktor Taksonomi BATAN > Reaktor Nuklir > Teknologi Reaktor > Sistem Reaktor |
Divisions: | BATAN > Pusat Reaktor Serba Guna IPTEK > BATAN > Pusat Reaktor Serba Guna |
Depositing User: | Administrator Repository |
Date Deposited: | 29 Oct 2018 07:44 |
Last Modified: | 31 May 2022 04:45 |
URI: | https://karya.brin.go.id/id/eprint/4130 |