Unggul Hartoyo, UH and Anto Setiawanto, AS and Yulius Sumarno, YS and Subiharto, Subiharto (2015) KAJIAN SISTEM PEMANTAU LAJU DOSIS GAMMA RUANG KENDALI UTAMA RSG-GAS. PROSIDING SEMINAR NASIONAL TEKNOLOGI DAN APLIKASI REAKTOR NUKLIR. ISSN 978-979-8500-67-1
15-unggul_fix 88-93.pdf
Download (186kB) | Preview
Abstract
KAJIAN UNJUK KERJA SISTEM PEMANTAU LAJU DOSIS GAMMA RUANG KENDALI UTAMA (RKU) RSG-GAS. Sistem pemantau laju dosis gamma RKU telah beroperasi selama 25 tahun lebih dan tidak pernah dimatikan. Hasil pengukuran ditampilkan di RKU dan terekam dalam rekorder. Pada periode tiga tahunan terakhir hasil pengukuran mengalami kenaikan pengukuran, sedangkan sumber radiasi yang berasal dari reaktor tidak mengalami peningkatan, oleh karena itu perlu dilakukan kajian terhadap unjuk kerja sistem. Kajian unjuk kerja sistem pemantau laju dosis gamma dilakukan dengan cara pengujian dan simulasi pada modul-modul pengolah pulsa menggunakan sumber pembangkit arus, sebagai pengganti pulsa dari detektor dan pengujian menggunakan sumber radiasi standar Cs-137. Hasil pengujian diperoleh bahwa pada modul-modul pengolah pulsa masih berfungsi dengan baik dan tidak terjadi penyimpangan. Pengujian menggunakan sumber radiasi standar terjadi penyimpangan yang cukup signifikan dengan nilai penyimpangan 54,8 %. Dari hasil tersebut dapat disimpulkan bahwa unjuk kerja sistem pemantau gamma di RKU telah mengalami penurunan unjuk kerja sehingga hasil pengukuran sudah tidak akurat dan detektor dengan jenis KG 151 SBL perlu dilakukan penggantian.
Kata kunci : laju dosis, gamma, detektor.
ABSTRACT
STUDY PERFORMANCE MONITORING SYSTEM OF GAMMA DOSE RATE CONTROL ROOM KEY (RKU) RSG-GAS. Gamma dose rate monitoring system RKU has been operating for 25 years and never turned off. The measurement results shown in RKU and recorded in the recorder. In the last three-year period increased measurement results of measurement, while the source of the radiation emanating from the reactor is not increased, therefore it is necessary to study on the performance of the system. Study of the performance of the gamma dose rate monitoring system is done by testing and simulating the pulse processing modules using current generation sources, in lieu of a pulse from the detector and testing using standard radiation sources Cs-137. The test results showed that the pulse processing modules still functioning well and no irregularities. Testing using standard radiation sources are significant deviations in the value of deviation of 54.8%. From these results it can be concluded that the gamma monitors system performance in RKU have decreased performance so that the measurement is not accurate and the detector with the type KG 151 SBL need replacement.
Keywords : Gamma dose rate monitoring system
Item Type: | Article |
---|---|
Subjects: | Taksonomi BATAN > Reaktor Nuklir > Teknologi Reaktor > Sistem Reaktor Taksonomi BATAN > Reaktor Nuklir > Teknologi Reaktor > Sistem Reaktor |
Divisions: | BATAN > Pusat Reaktor Serba Guna IPTEK > BATAN > Pusat Reaktor Serba Guna |
Depositing User: | Administrator Repository |
Date Deposited: | 29 Oct 2018 03:35 |
Last Modified: | 31 May 2022 04:54 |
URI: | https://karya.brin.go.id/id/eprint/4087 |