Clinical trial design of Boron Neutron Capture Therapy on breast cancer using D-D coaxial compact neutron generator as neutron source and Monte Carlo N-Particle simulation method

Pasaribu, Rosenti and Kusminarto, Kusminarto and Sardjono, Yohanes (2016) Clinical trial design of Boron Neutron Capture Therapy on breast cancer using D-D coaxial compact neutron generator as neutron source and Monte Carlo N-Particle simulation method. Indonesian Journal of Physics and Nuclear Appilication, 1 (1). ISSN 2549 -046X

[thumbnail of Clinical trial design of Boron Neutron Capture Therapy on breast cancer using D-D coaxial compact neutron generator as neutron source and Monte Carlo N-Particle simulation method] Text (Clinical trial design of Boron Neutron Capture Therapy on breast cancer using D-D coaxial compact neutron generator as neutron source and Monte Carlo N-Particle simulation method)
1316 - Published Version
Available under License Creative Commons Attribution.

Download (41kB)

Abstract

A clinical trial simulation of Boron Neutron Capture Therapy (BNCT) for breast cancer was conducted at National Nuclear Energy Agency Yogyakarta, Indonesia. This was motivated by high rate of breast cancer in the world, especially in Indonesia. BNCT is a type of therapy by nuclear reaction 10B(n,α)7Li that produces kinetic energy totaling 2.79 MeV. High Linear Energy Transfer (LET) radiation of α-particle and recoil 7Li would locally deposit their energy in a range of 5-9 μm, which corresponds to the human cell diameter. Fast neutron coming out of Compact Neutron Generator (CNG) was moderated using Fe and MgF2 material. A collimator, along with breast cancer and the corresponding organ at risk were designed compatible to Monte Carlo N-Particle X (MCNPX). The radiation were simulated by the MCNPX software and the physical quantities were counted by tally MCNPX codes. The highest neutron thermal flux was found at a depth of 1.4 cm on fat tissue. En face and upward intersection radiation techniques were adopted for the breast cancer radiation. The average dose rate of radiation used on breast cancer was 1.72×10-5 Gy/s for the en face method and 8.98×10-6 Gy/s for the upward intersection method. Dose 50±3 Gy was given into cancer cell, (4.18±0.06) ×10-2 Gy into heart and (8.16±0.06) ×10-2Gy into lung for 806.34 hours irradiation.

Item Type: Article
Subjects: Taksonomi BATAN > Reaktor Nuklir
Taksonomi BATAN > Reaktor Nuklir
Taksonomi BATAN > Reaktor Nuklir > Pemanfaatan Reaktor
Taksonomi BATAN > Reaktor Nuklir > Pemanfaatan Reaktor
Divisions: BATAN > Pusat Sains dan Teknologi Akselerator
IPTEK > BATAN > Pusat Sains dan Teknologi Akselerator
Depositing User: Administrator Repository
Date Deposited: 03 Jun 2018 10:56
Last Modified: 31 May 2022 04:45
URI: https://karya.brin.go.id/id/eprint/2777

Actions (login required)

View Item
View Item