VISUALISASI DISTRIBUSI SUHU WATER HEATING TANK UNTAI FASSIP-02 MENGGUNAKAN KAMERA INFRA MERAH (Dedy Haryanto, Giarno, Joko Prasetio Witoko, G. Bambang Heru K.,Mulya Juarsa, M. Hadi Kusuma)

Dedy Haryanto, DH and Giarno, GN and Joko Prasetio W, JPW and G. Bambang Heru K, GBHK and Mulya Juarsa, MJ and M. Hadi Kusuma, MHK (2019) VISUALISASI DISTRIBUSI SUHU WATER HEATING TANK UNTAI FASSIP-02 MENGGUNAKAN KAMERA INFRA MERAH (Dedy Haryanto, Giarno, Joko Prasetio Witoko, G. Bambang Heru K.,Mulya Juarsa, M. Hadi Kusuma). In: Seminar Nasional Teknologi Energi Nuklir 2019 Padang, 18 September 2019 253 ISSN: 2355-7524, 18 September 2019, Universitas ANDALAS Fakultas Teknik Padang Sumatera Barat.

Full text not available from this repository.

Abstract

ABSTRAK
VISUALISASI DISTRIBUSI SUHU WATER HEATING TANK UNTAI FASSIP-02
MENGGUNAKAN KAMERA INFRA MERAH. Proses pemanasan air di dalam water heating
tank pada Untai FASSIP-02 merupakan proses penting dalam mengetahui fenomena
sirkulasi alamiah yang terjadi. Pada saat untai FASSIP-02 dioperasikan, informasi mengenai
distribusi suhu di water heating tank diperlukan sebagai salah satu metode untuk
mengetahui efektifitas pemanas yang diberikan dan mengetahui waktu pemanas yang
dibutuhkan. Tujuan penelitian ini adalah mengetahui distribusi suhu di water heating tank
dan waktu pemanasan yang dibutuhkan agar air mencapai suhu yang diinginkan. Metode
yang dilakukan adalah memvisualisasikan distribusi suhu pada permukaan dinding luar
water heating tank dengan menggunakan kamera infra merah dan menghitung waktu
pemanasan yang dilakukan. Hasil yang didapatkan menunjukkan bahwa waktu pemanasan
air yang dibutuhkan adalah pada rentang 100-170 menit bergantung pada daya heater yang
diberikan. Kamera infra merah dapat memvisualisasikan distribusi suhu dinding luar water
heating tank dengan sangat baik dan dapat diandalkan untuk mengetahui informasi suhu
secara cepat pada saat proses eksperimen berlangsung.
Kata Kunci : visualisasi suhu, water heating tank, kamera infra merah, FASSIP-02
ABSTRACT
VISUALIZATION OF THE WATER HEATING TANK TEMPERATURE DISTRIBUTION AT
FASSIP-02 LOOP USING RED INFRA CAMERA. The process of heating water in a water
heating tank in FASSIP-02 loop is an important process in knowing the natural circulation
phenomena that occur. When the FASSIP-02 loop is operated, information about the
temperature distribution in the water heating tank is needed as one method to determine the
effectiveness of the heateing provided and to know the required heating time. The purpose
of this study is to determine the temperature distribution in the water heating tank and the
heating time needed so that the water reaches the desired temperature. The method used is
to visualize the temperature distribution on the surface of the outer wall of the water heating
tank by using an infrared camera and calculating the heating time. The results obtained
indicate that the heating time of water needed is in the range of 100-170 minutes depending
on the heater power given. Infrared cameras can visualize the temperature distribution of the
outer walls of the water heating tank very well and can be relied upon to find out temperature
information quickly during the experimental process.
Keywords: temperature visualization, water heating tank, infrared camera, FASSIP-02

Item Type: Conference or Workshop Item (Paper)
Subjects: Taksonomi BATAN > Keselamatan dan Keamanan Nuklir
Taksonomi BATAN > Keselamatan dan Keamanan Nuklir
Divisions: BATAN > Pusat Teknologi dan Keselamatan Reaktor Nuklir
IPTEK > BATAN > Pusat Teknologi dan Keselamatan Reaktor Nuklir
Depositing User: Iskandar Alisyahbana Adnan
Date Deposited: 23 Jul 2020 00:25
Last Modified: 30 May 2022 08:38
URI: https://karya.brin.go.id/id/eprint/9895

Actions (login required)

View Item
View Item