Giarno, GN and Joko Prasetio W, JPW and G.B. Heru, GBH and Ainur Rosidi, AR and Dedy Haryanto, DH and Mulya Juarsa, MJ (2019) KARAKTERISASI PEMANASAN DAN PENDINGINAN UNTAI FASSIP-01 BERDASARKAN KEMAMPUAN PENDINGINAN UNTAI HEAT SINK SYSTEM (Giarno, Joko PW., G.B. Heru K., Ainur Rosidi, Dedy Haryanto, Mulya Juarsa, Deswandri). In: Seminar Nasional Teknologi Energi Nuklir 2019 Padang, 18 September 2019 239 ISSN: 2355-7524, 18 September 2019, Universitas ANDALAS Fakultas Teknik Padang Sumatera Barat.

Full text not available from this repository.

Abstract

ABSTRAK
KARAKTERISASI PEMANASAN DAN PENDINGINAN UNTAI FASSIP-01
BERDASARKAN KEMAMPUAN PENDINGINAN UNTAI HEAT SINK SYSTEM. Konsep
keselamatan pasif digunakan untuk meningkatkan keamanan dan keselamatan PLTN.
Sistem pasif merupakan sistem pembuang kalor dengan mengasumsikan tidak tersedianya
pompa serta gagal beroperasinya generator. Untuk mendalami teknologi sistem pasif telah
dilakukan eksperimen sirkulasi alam menggunakan untai FASSIP-01. Sistem pemanas
kontak langsung adalah sumber panas (BCH-02) secara langsung memanasi air dalam pipa
rektangular tanpa pemanasan air dalam tangki. Sistem pemanas kontak langsung bertujuan
untuk memperoleh waktu pemanasan yang lebih cepat dan efisien, dibandingkan dengan
pemanas kontak tidak langsung yang menggunakan media air dalam tangka yang
dipanaskan terlebih dahulu. Sistem pendingin kontak tidak langsung yaitu pendinginan air
dalam tangki oleh mesin refrigerasi dan air dalam tangki mendinginkan air dalam pipa
rektangular. Data hasil eksperimen dibuat grafik dan diperoleh karakteristik proses
pemanasan yaitu semakin tinggi posisi pipa section maka proses pemanasan semakin cepat
sedangkan proses pendinginan terjadi sebaliknya yaitu semakin rendah posisi pipa section,
maka semakin cepat proses pendinginan. Untai FASSIP-01 dengan sistem pemanas kontak
langsung lebih baik dan lebih cepat waktunya dibandingkan dengan sistem pemanas kontak
tidak langsung.
Kata Kunci : Karakterisasi, pemanasan, pendinginan, untai FASSIP-01
ABSTRACT
CHARACTERIZATION OF HEATING AND COOLING FOR FASSIP-01 BASED ON
COOLING ABILITY FOR HEAT SINK SYSTEM. The passive safety concept is used to
improve the security and safety of nuclear power plants. The passive system is a heat
removal system assuming the unavailability of pumps and failure of the operation of a diesel
generator. To explore passive system technology, natural circulation experiments have been
carried out using the FASSIP-01 loop. The direct contact heating system is a heat source
(BCH-02) which directly heats water in rectangular pipes without heating the water in the
tank. Direct contact heating system aims to obtain a faster and more efficient heating time,
compared to indirect contact heaters that use water media in a preheated case. The indirect
contact cooling system is cooling the water in the tank by a refrigeration machine and the
water in the tank cools the water in rectangular pipes. The experimental data is graphed and
the heating process characteristics are obtained, the higher the position of the section pipe,
the faster the heating process, while the cooling process is the opposite, namely the lower
the section pipe position, the faster the cooling process. The FASSIP-01 loop with direct
contact heating system is better and faster in time compared to indirect contact heating
system.
Keywords: Characterization, heating, cooling, FASSIP-01 loop.

Item Type: Conference or Workshop Item (Paper)
Subjects: Taksonomi BATAN > Keselamatan dan Keamanan Nuklir
Taksonomi BATAN > Keselamatan dan Keamanan Nuklir
Divisions: BATAN > Pusat Teknologi dan Keselamatan Reaktor Nuklir
IPTEK > BATAN > Pusat Teknologi dan Keselamatan Reaktor Nuklir
Depositing User: Iskandar Alisyahbana Adnan
Date Deposited: 23 Jul 2020 00:25
Last Modified: 30 May 2022 08:39
URI: https://karya.brin.go.id/id/eprint/9893

Actions (login required)

View Item
View Item