Joko Prasetio W, JPW and Ainur Rosidi, AR (2019) UJI FUNGSI PENGISIAN NITROGEN CAIR PADA BAGIAN KRIOGENIK FASILITAS UJI SISTEM PEMURNIAN HELIUM (Joko Prasetio W, Ainur Rosidi). In: Seminar Senten PADANG Sumatera Barat 2019, 18 September 2019, Universitas ANDALAS Fakultas Teknik Padang Sumatera Barat.

Full text not available from this repository.

Abstract

ABSTRAK
UJI FUNGSI PENGISIAN NITROGEN CAIR PADA BAGIAN KRIOGENIK
FASILITAS UJI SISTEM PEMURNIAN HELIUM. Sistem pemurnian helium
merupakan sistem bantu yang sangat penting di reaktor berpendingin gas temperatur tinggi.
Sistem tersebut berfungsi untuk menghindari oksidasi grafit dan korosi pada komponen dan
struktur. Bagian kriogenik merupakan komponen utama sistem pemurnian helium yang
berfungsi untuk menyerap pengotor pada gas helium berupa gas krypton sebanyak 3%, gas
oksigen 2%, gas nitrogen 2% yang beroperasi pada temperatur rendah. Tujuan dari
penelitian ini adalah untuk menguji kemampuan tangki kriogenik menahan nitrogen cair pada
temperature rendah sampai -150 ºC. Metode yang digunakan adalah memvakum tangki
kriogenik sampai tercapai tekanan -50 bar, kemudian melakukan pengisian nitrogen cair
dengan cara membuka katup V.01 pada saluran pipa dan membuka katup flashing. Hasil
pengujian menunjukkan bahwa tangki kriogenik mampu menahan nitrogen cair pada
temperatur rendah yaitu -160 ºC dengan durasi waktu pengisian selama 105 menit.
Kata kunci : Sistem pemurnian helium, kriogenik, RDNK
Abstract
FUNCTION TESTS ON FILLING NITROGEN OF LIQUIDS IN THE CHROGENIC PART OF
FACILITIES TEST HELIUM PURIFICATION SYSTEM. The helium purification system is a
very important auxiliary system in high temperature gas cooled reactors. The system
functions to avoid graphite oxidation and corrosion of components and structures. The
cryogenic part is the main component of the helium purification system that functions to
absorb impurities in the helium gas in the form of krypton gas as much as 3%, oxygen gas
2%, nitrogen gas 2% which operate at low temperatures. The purpose of this study was to
examine the ability of cryogenic tanks to hold liquid nitrogen at low temperatures up to -150
ºC.The method used is to vacuum the cryogenic tank until a pressure of -50 bar is reached,
then filling liquid nitrogen by opening the V.01 valve on the pipeline and opening the flashing
valve. The test results show that the cryogenic tank is able to hold liquid nitrogen at a low
temperature of -160 ºC with a filling time duration of 105 minutes.
Keywords: Helium purification system, Cryogenic, RDNK

Item Type: Conference or Workshop Item (Paper)
Subjects: Taksonomi BATAN > Keselamatan dan Keamanan Nuklir
Taksonomi BATAN > Keselamatan dan Keamanan Nuklir
Divisions: BATAN > Pusat Teknologi dan Keselamatan Reaktor Nuklir
IPTEK > BATAN > Pusat Teknologi dan Keselamatan Reaktor Nuklir
Depositing User: Iskandar Alisyahbana Adnan
Date Deposited: 07 Jul 2020 06:22
Last Modified: 30 May 2022 08:39
URI: https://karya.brin.go.id/id/eprint/9873

Actions (login required)

View Item
View Item