KAJIAN PENGARUH KELEMBABAN PADA PENGUKURAN SENSOR DETEKTOR FLUKS NEUTRON RSG-GAS. (Kiswanta1, Sudarno1, Sujarwono2, Ranji Gusman2, Heri Suherkiman2 1 Pusat Teknologi dan Keselamatan Reaktor Nuklir (PTKRN) – BATAN 2 Pusat Reaktor Serba Guna (PRSG) - BATAN Email : kiswanta-igos@batan.go.id)

Kiswanta, KW and Sudarno, SD and Sujarwono, Sujarwono and Ranji Gusman, RG and Heri Suherkiman, HS (2019) KAJIAN PENGARUH KELEMBABAN PADA PENGUKURAN SENSOR DETEKTOR FLUKS NEUTRON RSG-GAS. (Kiswanta1, Sudarno1, Sujarwono2, Ranji Gusman2, Heri Suherkiman2 1 Pusat Teknologi dan Keselamatan Reaktor Nuklir (PTKRN) – BATAN 2 Pusat Reaktor Serba Guna (PRSG) - BATAN Email : kiswanta-igos@batan.go.id). In: Prosiding Seminar Nasional Teknologi Energi Nuklir 2019, 18 September 2029, Universitas ANDALAS Fakultas Teknik Padang Sumatera Barat.

Full text not available from this repository.

Abstract

ABSTRAK
KAJIAN PENGARUH KELEMBABAN PADA PENGUKURAN SENSOR DETEKTOR
FLUKS NEUTRON RSG-GAS. Reaktor Serba Guna GA. Siwabessy (RSG-GAS sudah
beroperasi lebih dari 30 tahun. Faktor kelembaban dapat menyebabkan terjadi pergeseran
nilai sinyal pada pengukuran bagian analog, degradasi komponen, korosi bahkan sering
mengalami kerusakan. Kerusakan tersebut menyebabkan pengukuran tidak tepat dan
mempengaruhi sinyal-sinyal RPS. Juga menyebabkan unbalance, proses balance menjadi
lebih lama bahkan scram. Untuk itu perlu dilakukan kajian pengaruh kelembaban terhadap
proses pengukuran pada detektor fluks neutron RSG-GAS. Kajian meliputi kondisi titik
pengukuran, transduser, defais, perangkat dan tampilan baik secara visual, sinyal listrik,
karakteristik sinyal, ketelitian, kestabilan, error, dan pengaruh lingkungan. Metode penelitian
dilakukan dengan mengukur tingkat kelembaban, pemberian semburan udara SCA ke dalam
detektor guide tube untuk mengurangi kelembaban, mengukur sinyal listrik pada setiap
bagian analog dan menganalisis pengaruh kelembaban terhadap rangkaian pengukuran
detektor fluks neutron. Dari data bagian detektor fluks neutron tersebut dievaluasi untuk
mendukung kajian teknis penuaan RSG-GAS. Hasil pengukuran tingkat kelembaban pada
pengukuran fluks neutron RSG-GAS sudah dapat dilakukan dengan baik. Pengaruh
kelembaban udara sangat signifikan terhadap hasil pengukuran sinyal listrik. Pemberian
udara kering dari kompressor ke dalam guide tube detektor neutron terbukti sangat efektif
untuk menurunkan kelembaban udara dari sekitar 62% menjadi 6% sedangkan temperatur
tetap sekitar 21-22°C. Sedangkan tingkat kestabilan sistem dan ketelitian bagian penguat
amplifier masing-masing detektor fluks neutron masih bagus sekitar 98%.
Kata kunci: Detektor fluks neutron, pengukuran, kelembaban, sinyal listrik, degradasi.
ABSTRACT
STUDY OF HUMIDITY EFFECT FOR THE NEUTRON FLUKS DETECTORS
MEASUREMENT OF RSG-GAS. The GA Multipurpose Reactor. Siwabessy (RSG-GAS has
been operating for more than 30 years. The moisture factor can cause a shift in signal values
in analog section measurements, component degradation, corrosion and even damage. The
damage causes improper measurement and affects RPS signals. Also causes unbalance the
balance process takes longer and even scams, so it is necessary to study the effect of
humidity on the measurement process on RSG-GAS neutron flux detectors.The study
includes conditions of measurement points, transducers, defects, devices and displays both
visually, electrical signals, signal characteristics accuracy, stability, error, and environmental
influences.The research method was carried out by measuring the moisture level, giving
SCA air bursts into guide tube detectors to reduce humidity, measuring electrical signals in
each analog section and analyzing the effect of humidity on the neutron flux detector
measurement circuit. da The neutron flux detector section was evaluated to support the
technical review of aging RSG-GAS. The results of the measurement of the level of moisture
in the measurement of RSG-GAS neutron flux can be done well. The effect of air humidity is
very significant on the results of measuring electrical signals. Giving dry air from the
compressor to the neutron detector guide tube proved to be very effective in reducing air
humidity from about 62% to 6% while the fixed temperature was around 21-22 ° C. While the
level of system stability and accuracy of the amplifier amplifier parts of each neutron flux
detector is still good at around 98%.
Keywords: Neutron flux detector, measurement, humidity, electrical signal, degradation.

Item Type: Conference or Workshop Item (Paper)
Subjects: Taksonomi BATAN > Keselamatan dan Keamanan Nuklir
Taksonomi BATAN > Keselamatan dan Keamanan Nuklir
Divisions: BATAN > Pusat Teknologi dan Keselamatan Reaktor Nuklir
IPTEK > BATAN > Pusat Teknologi dan Keselamatan Reaktor Nuklir
Depositing User: Iskandar Alisyahbana Adnan
Date Deposited: 07 Jul 2020 06:22
Last Modified: 30 May 2022 08:39
URI: https://karya.brin.go.id/id/eprint/9872

Actions (login required)

View Item
View Item