IDENTIFIKASIMIKROBADALAMAIR PENDINGIN PRIMERRSG-GAS (Itjeu Karliana, Diah Dwiana L, Sumijanto, Hendro Tjahyono, M. Hadi, Tjipta S Pusat Pengembangan Teknologi Keselamatan Nuklir) Murahmah, Diyah Erlina

itjeu karliana, IK and diah dwiyana lestari, ddl and Sumijanto, ST and Hendro Tjahjono, HT and M. Hadi Kusuma, MHK and Murahmah, MR and Diah Erlina Lestari, DEL (2005) IDENTIFIKASIMIKROBADALAMAIR PENDINGIN PRIMERRSG-GAS (Itjeu Karliana, Diah Dwiana L, Sumijanto, Hendro Tjahyono, M. Hadi, Tjipta S Pusat Pengembangan Teknologi Keselamatan Nuklir) Murahmah, Diyah Erlina. In: Prosiding Presentasi Ilmiah Teknologi Keselamatan Nuklir X ISSN No. 1410-0533, 26 Pebruari 2003, Pusat Teknologi dan Keselamatan Reaktor Nuklir.

Full text not available from this repository.

Abstract

ABSTRAK
IDENTIFIKASI MIKROBA DALAM AIR PENDINGIN PRIMER RSG-GAS. Telah dilakukan identifikasi kandungan mikroba pada air pendingin primer RSG-GAS. Mikroba merupakan jasad renik yang hidup dan berada di seluruh tempat baik yang membutuhkan oksigen (aerob) maupun tanpa oksigen (anaerob).Tujuan identifikasi adalah untuk mengenal jenis mikroba , dan menelusuri asal mikroba pencemar. Metoda penelitian ini dilakukan dengan cara sampling air dari pemasok air tangki reaktor (air demin ), air sebelum melalui resin penukar ion (inlet) dan air sesudah melalui resin penukar ion (outlet). Ketiga cuplikan diperiksa secara duplo sesuai dengan prinsip mikrobiologi mulai dari pertumbuhan dalam media Trypticase Soy Agar (TSA), kemudian mengamati bentuknya dalam media pertumbuhan, mencuplik, menginokulasikannya dalam media nutrien agar dan mac conskey agar dan menghitung jumlah bakteri dengan menggunakan mikroskop. Hasil identifikasi diketahui adanya bakteri berbentuk batang pendek dan memberikan reaksi gram negatif menunjukkanbahwa cuplikan bakteri adalah E.Coli. . Berdasarkan pengamatan mikrobiologi ternyata ditemukan bakteri aerob pada air demin, air inlet, air outlet masing-masing dengan jumlah 81,0 x 10 2 koloni/ml, 41,5 x 10 2 koloni/ml, 36,0 x 10 koloni/ml dan bakteriE.Coli 29.0 x 10 2 koloni/ml, 30,5 x 10 koloni/ml 1,0 x 10 koloni/ml.Dari hasil pengamatan adanya kecenderungan kandungan bakteri yang menurun berdasarkan pola pengambilan sampel air. Tidak ditemukan adanya Sulphur Reducing Bacteri dalam semua cuplikan pada kondisi pertumbuhan aerob. Keberadaan E.Coli diduga berasal dari sumber air baku dengan spesifikasi tertentu yang telah mengalami proses sebagai pemasok air demin. E.Coli juga masih teridentifikasi dalamsampel air inlet dan sampel air outlet meskipunmengalami beberapa tahap pembersihan dan radiasi.
ABSTRACT
MICROBES IDENTIFICATION IN PRIMARY COOLING WATER OF RSG-GAS. Have been identified content of microbes in primary cooling water of RSG-GAS. Microbes represent microorganism which live and reside in the totality place both for requiring oxygen ( aerob) and also without oxygen ( anaerob). Target identify are recognize microbe type, and trace origin of microbes contaminant. Method of research conducted by water sampling from water supply of reactor tank ( demin water ), water before through resin ion exchanger ( water inlet) and water after through resin ion exchanger ( water outlet). All of samples checked by duplo as according to microbiological principle start from growth in media of Trypticase Soy Agar ( TSA), then perceive its for in growth media, traced, inoculated in media of Nutrient Agar and Mac Conskey Agar and counted bacteria by using microscope. To identify type of bacteria which growth then perceived compared to shape, reaction of Gram of positive/negative with bacteria E.Coli and Sulphur Reducing Bacteria (SRB) . The result of identification shown that bacteria in shape of short bar and give reaction of Gram negative indicated that samples of bacteria is E.Coli. According to microbiological identification at demin water, water inlet, water outlet are found 81,0 x 102 colony/ml, 41,5 x 102 colony/ml, 36,0 x 10 colony/ml and bacteria E.Coli are 29.0 x 102 colony/ml, 30,5 x 10 colony/ml, 1,0 x 10 colony/ml. The all samples totally are contaminated by E.Coli .Seen from result that the existence of bacteria tends to pattern of intake of water samples. The existence of Sulphur Reducing Bacteria is not found at all samples in aerob growth condition. Existence of E.Coli probable come from source of water supply with the certain specification is treat of process as raw of demin water. E.Coli also still be identified in water inlet sample and water outlet sample due through out of cleaning and radiation.

Item Type: Conference or Workshop Item (Paper)
Subjects: Taksonomi BATAN > Keselamatan dan Keamanan Nuklir
Taksonomi BATAN > Keselamatan dan Keamanan Nuklir
Divisions: BATAN > Pusat Teknologi dan Keselamatan Reaktor Nuklir
IPTEK > BATAN > Pusat Teknologi dan Keselamatan Reaktor Nuklir
Depositing User: Administrator Repository
Date Deposited: 11 May 2020 05:53
Last Modified: 31 May 2022 03:46
URI: https://karya.brin.go.id/id/eprint/9831

Actions (login required)

View Item
View Item