Preliminary Experiment of U-Shaped Heat Pipe as Passive Cooling System in High Temperature Gas-Cooled Reactor Cooling Tank

M. Hadi Kusuma, MHK and Anhar Riza Antariksawan, ARA and Giarno, GN and sri ismarwanti, si and Mulya Juarsa, MJ and Dedy Haryanto, DH and Surip Widodo, SW and tanti ardiyati, ta (2019) Preliminary Experiment of U-Shaped Heat Pipe as Passive Cooling System in High Temperature Gas-Cooled Reactor Cooling Tank. In: Seminar SENTEN - 2018 Palembang, 4 - 5 Juli 2018, UNIVERSITAS SRIWIJAYA - PALEMBANG 2018.

Full text not available from this repository.

Abstract

Abstract
When station blackout occurs on high temperature gas-cooled reactor, the decay heat will be absorbed by a residual heat dissipation system (known as cooling tank) which connected to the reactor cavity cooling system. The U-shaped heat pipe as passive cooling system is proposed as new feature of technology to absorb the decay heat in the high temperature gas-cooled reactor cooling tank, and to keep the water remains in its operating temperature and level. This research objective is to know thermal resistance of U-shaped heat pipe scale model based on variation of heat load and coolant velocity. The influence of water temperature in the circulating thermostatic bath as heat load on evaporator section and air velocity which flowed into the horizontal condenser fin were investigated experimentally. The heat loads were varied at water temperature of 45, 50, and 60°C. The air velocities were varied at 0.45, 0.83, and 1.06 m/s. The experiment result showed the lowest thermal resistance of 0.000027±0.0000000593 °C/W when U-shaped heat pipe was operated at hot water temperature of 60°C and air velocity of 1.06 m/s. The investigation result can be used as a model and initial knowledge to design large scale of U-shaped heat pipe as a passive cooling system in cooling tanks connected to high temperature gas-cooled reactor cavity cooling system. This result is also useful regarding to the thermal management of passive cooling process in cooling tank and it can improve the nuclear safety and be able to overcome the thermal problems caused by station blackout in high temperature gas-cooled reactor.
Mukhsinun Hadi Kusuma1, Anhar Riza Antariksawan1, Giarno1, Sri Ismarwanti2, Mulya Juarsa1, Dedy Haryanto1, Surip Widodo1 and Tanti Ardiyati3

Item Type: Conference or Workshop Item (Paper)
Subjects: Taksonomi BATAN > Keselamatan dan Keamanan Nuklir
Taksonomi BATAN > Keselamatan dan Keamanan Nuklir
Divisions: BATAN > Pusat Teknologi dan Keselamatan Reaktor Nuklir
IPTEK > BATAN > Pusat Teknologi dan Keselamatan Reaktor Nuklir
Depositing User: Iskandar Alisyahbana Adnan
Date Deposited: 21 Apr 2020 06:50
Last Modified: 30 May 2022 08:39
URI: https://karya.brin.go.id/id/eprint/9503

Actions (login required)

View Item
View Item