PEVALUASI NILAI TERENDAH SISTEM PEMANTAU LAJU DOSIS GAMMA DI RSG-GAS

Yulius Sumarno, YS and Nazly Kurniawan, NK and Subiharto, Subiharto (2013) PEVALUASI NILAI TERENDAH SISTEM PEMANTAU LAJU DOSIS GAMMA DI RSG-GAS. Buletin "Reaktor". pp. 1-7. ISSN ISSN: 0216-2695

[thumbnail of 1.EVALUASI NILAI TERENDAH SISTEM PEMANTAU LAJU DOSIS GAMMA (1-8).pdf]
Preview
Text
1.EVALUASI NILAI TERENDAH SISTEM PEMANTAU LAJU DOSIS GAMMA (1-8).pdf

Download (451kB) | Preview

Abstract

EVALUASI NILAI TERENDAH SISTEM PEMANTAU LAJU DOSIS GAMMA DI RSG-GAS. Telah dilakukan evaluasi umur kerja detektor UJA dengan tujuan untuk mengetahui apakah nilai terendah yang disetting di alat sejak tahun 1985 masih valid. Evaluasi dilakukan dengan cara menghitung aktivitas sumber standar Cs-137 yang ada dalam detektor alat tersebut, serta menghitung paparan yang ditimbulkan. Berdasarkan hasil perhitungan dan pengamatan diketahui bahwa dari ketigabelas sistem UJA, setting nilai terendah sebesar 0,50 Volt masih dapat digunakan, kecuali untuk UJA02 CR002 dan UJA09 CR001. Untuk kedua alat tersebut perlu dilakukan setting ulang nilai terendah dari 0,50 Volt menjadi 0,10 Volt. Hal ini dapat terjadi karena proses penuaan yang mengakibatkan komponen elektronik lemah dan tidak akurat lagi untuk mendeteksi sinyal dengan dosis rendah.

Kata kunci : Detektor, dosis gamma, nilai batas terendah

ABSTRACT

EVALUATION OF THE LOWEST LIMIT VALUE SETTING OF GAMMA DOSE RATE MONITORING SYSTEM AT THE RSG – GAS. It has been carried out an evaluation of the lowest limit value of gamma dose rate monitoring system in order to recognize whether the lowest limit value setting, which has been made since 1985, still applicable for current time. Evaluation was carried out by calculating both the current activity of Cs-137 present inside the detector of the systems, and the level of gamma dose rate generated by that radioactive sources. The calculation and observation results from the thirteen UJA systems showed that the lowest setting of 0.50 Volt is still applicable. Except for the UJA02 CR002 and UJA09 CR001. For both systems, the lowest voltage setting have to be reset or turned down from 0.50 Volt to be 0.10. This is caused by degradation of the component due to aging process yields its electronic system fail to detect low signal.

Key word : Detector, gamma dose rate, lowest limit value

Item Type: Article
Subjects: Taksonomi BATAN > Keselamatan dan Keamanan Nuklir > Keselamatan Lingkungan > Analisis Mengenai Dampak Lingkungan
Taksonomi BATAN > Keselamatan dan Keamanan Nuklir > Keselamatan Lingkungan > Analisis Mengenai Dampak Lingkungan
Divisions: BATAN > Pusat Reaktor Serba Guna
IPTEK > BATAN > Pusat Reaktor Serba Guna
Depositing User: Administrator Repository
Date Deposited: 18 Jun 2019 03:18
Last Modified: 31 May 2022 09:16
URI: https://karya.brin.go.id/id/eprint/8998

Actions (login required)

View Item
View Item