EVALUASI PEMANTAUAN DOSIS RADIASI DAN KONTAMINASI PEKERJA RADIASI REAKTOR GA.SIWABESSY TAHUN 2007

Sunarningsih, Sunarningsih and Anastasia Lilik W, ALW and Yosep Susantiyono, YS (2009) EVALUASI PEMANTAUAN DOSIS RADIASI DAN KONTAMINASI PEKERJA RADIASI REAKTOR GA.SIWABESSY TAHUN 2007. In: Prosiding Seminar Nasional Teknologi dan Aplikasi Reaktor Nuklir.

[thumbnail of 30_sunarningsih.pdf]
Preview
Text
30_sunarningsih.pdf

Download (484kB) | Preview

Abstract

EVALUASI PEMANTAUAN DOSIS RADIASI DAN KONTAMINASI PEKERJA RADIASI REAKTOR GA.SIWABESSY TAHUN 2007. Hasil pemantauan penerimaan dosis radiasi dengan TLD badge selama perioda tahun 2007, menunjukkan bahwa Dosis Ekivalen Seluruh Tubuh (DEST) atau Hp 10 , rata-rata tertinggi terjadi pada tri wulan I, untuk bidang sistem reaktor yaitu 0,33 ± 0,29 mSv, dan rata rata terendah untuk bidang Unit Pengamanan Nuklir (UPN) dan Unit Jaminan Mutu (UJM) yaitu tak terdeteksi.. Dosis tertinggi, terjadi pada tri wulan III yaitu 3,57 mSv unuk pekerja radiasi bidang operasi reaktor, sedangkan dosis terendah yaitu tak terdeteksi, untuk bidang UPN dan UJM. Dosis tahunan tertinggi adalah pekerja radiasi dari bidang operasi reaktor PRSG yaitu 7,30 mSv .Untuk pemantauan dosis yang dilakukan dengan menggunakan alat Whole Body Counting (WBC) menunjukkan bahwa tingkat kontaminasi radionuklida hasilaktivasi dan fisi didalam tubuh tidak terdeteksi. Untuk pemantauan kontaminasi tinggi pada pakaian kerja tahun 2007 ada 34 kasus, yang sebagian besar adalah pekerja radiasi dari bidang operasi reaktor dan sistem Reaktor. Dosis personil yang diterima pekerja radiasi tersebut masih jauh dibawah Nilai Batas Dosis (NDB) pertahun yang diperkenankan oleh IAEA yaitu (20 mSv/tahun) dan juga BAPETEN maka tingkat keselamatan radiasi personil PRSG masih dapat dipertanggung jawabkan.

Kata kunci : Dosis radiasi personil

ABSTRACT

EVALUATION OF RADIATION DOSES AND CONTAMINATION MONITORING OF THE GA.SIWABESSY REACTOR RADIATION WORKERS IN YEAR 2007. Monitoring result of radiation doses acceptance by TLD badge indicated that the highest mean of equivalent doses in the entire body (DEST) or Hp 10 was 0.33 ± 0.29 mSv.It was received by personil working at the reactor system division during the first quarter of 2007.While the lowest mean, undefectable, was recived by people working at the security unit (UPN) and at the quality assurance unit (UJM). The highest radiation doses during the thirth quarter is received by worker at the reactor operation division by the magnitute of 3.57 mSv. The undetec table lowest radiation doses were received by the UPN and UJM worker. The highest doses in the 2007 of 7.30 mSv was received by personil at the reactor operation division. Doses at the body monitored by whole body counting (WBC) demonstrated that nuclides contamination activation and fission product were undetectable. Clothes contamination were exercises by 34 radiation workers those belong to reactor operation division and reactor system division. Fortunately those radiation doses received by radiation workers were still at the range of IAEA and BAPETEN permissible value of 20 mSv/year then radiation safety is pretty assured

Key word : Personnel doses radiation

Item Type: Conference or Workshop Item (Paper)
Subjects: Taksonomi BATAN > Keselamatan dan Keamanan Nuklir > Keselamatan Radiasi dan Kesehatan kerja > Keselamatan dan Kesehatan Kerja
Taksonomi BATAN > Keselamatan dan Keamanan Nuklir > Keselamatan Radiasi dan Kesehatan kerja > Keselamatan dan Kesehatan Kerja
Divisions: BATAN > Pusat Reaktor Serba Guna
IPTEK > BATAN > Pusat Reaktor Serba Guna
Depositing User: Administrator Repository
Date Deposited: 18 Feb 2019 07:28
Last Modified: 31 May 2022 03:33
URI: https://karya.brin.go.id/id/eprint/8697

Actions (login required)

View Item
View Item