Setiawan, Duyeh and Febrian, Muhammad Basit and Setiadi, Yanuar (2018) Separation Of Radioisotope 113m In Using Column Chromatography Based on Silica Gel Matrix. Jurnal Molekul, 13 (2). pp. 162-171. ISSN 1907-9761
403
Download (29kB)
Abstract
Radioisotope indium-113m (113mIn) with half-life, T1/2 = 1.7 hours and gamma energy, E = 391 keV is suitable and meets the criteria as radiotracer in industry. 113mIn radioisotope was obtained from tin-113 decay(113Sn, T1 / 2 = 115 days) of 112Sn (n,) 113Sn neutron activation in nuclear reactor. The process of separation of radioisotope 113mIn using column chromatography method based on silica gel matrix using 0.05 M HCI
solution. Radionuclide and radiochemical purity tests were performed using the gamma-spectrometry method
and paper chromatography. The final product specification in the form of 113mInCl3 is clear solution, pH 2,
obtained yield of 81.83%, radionuclide purity of 90.22%, radiochemical purity of 91.61 ± 0,29% and stable
for 3 days at room temperature.
Item Type: | Article |
---|---|
Subjects: | Taksonomi BATAN > Isotop dan Radiasi Taksonomi BATAN > Isotop dan Radiasi > Produksi Isotop dan Sumber Radiasi > Teknik Produksi Radioisotop Taksonomi BATAN > Reaktor Nuklir > Pemanfaatan Reaktor > Iradiasi Target Taksonomi BATAN > Reaktor Nuklir > Pemanfaatan Reaktor > Iradiasi Target |
Divisions: | BATAN > Pusat Sains dan Teknologi Nuklir Terapan IPTEK > BATAN > Pusat Sains dan Teknologi Nuklir Terapan |
Depositing User: | Administrator Repository |
Date Deposited: | 17 Feb 2019 05:08 |
Last Modified: | 02 Jun 2022 03:17 |
URI: | https://karya.brin.go.id/id/eprint/8662 |