TH Rina M, THRM (2006) PENERAPAN METODE AAN KOMPARATIF PADA PENGUJIAN UNSUR-UNSUR DENGAN WAKTU PARUH MEDIUM DI LAB. AAN PRSG. In: PROSIDING HASIL PENELITIAN PRSG.
23Th Rina.pdf
Download (233kB) | Preview
Abstract
PENERAPAN METODE AAN KOMPARATIF PADA PENGUJIAN UNSUR-UNSUR DENGAN WAKTU PARUH MEDIUM DI LAB. AAN PRSG, Metode AAN adalah suatu metode pengujian tidak baku. Pada penelitian sebelumnya telah dilakukan pengujian/validasi metode AAN instrumental untuk beberapa unsur dengan waktu paruh panjang. Sebagai lanjutan pada penelitian ini telah dilakukan pengujian unsur-unsur dengan waktu paruh medium menggunakan metode AAN di Lab. AAN PRSG. Bahan standar tersertifikasi yang digunakan untuk pengujian adalah NIST 1573a Tomato Leaves, SRM 2702 Inorganic Marine Sediment, SRM 1547 Peach Leaves, SRM 2780 Hard Rock Mine Waste, dan SRM 2711 Montana Soil. Iradiasi dilakukan pada system rabbit RSG pada fluks neutron thermal 1013 n.cm-2.det-1. dengan waktu iradiasi 5 – 10 menit. Hasil pengujian parameter akurasi dan presisi, memberikan hasil yang cukup bagus untuk unsur-unsur yang terkuantifikasi dengan jenis tergantung matriknya. As pada pengujian akurasi dan presisi kurang bagus terutama untuk orde konsentrasi yang relative rendah. Tetapi secara umum metode ini layak digunakan sebagai metode pengujian di Lab. AAN.
Kata kunci : analisis aktivasi netron, presisi, akurasi, bahan standar
ABSTRACT
APLICATION OF NAA-COMPARATIVE METHOD ON THE ANALYSIS OF ELEMENTS HAVE MEDIUM HALF TIME IN AAN LABORATORY OF PRSG. NAA method is a non standard testing method. The INAA method had been validated for the elements with long half time. On this research was done validation for elements with medium half time. The NIST 1573a Tomato Leaves, SRM 2702 Inorganic Marine Sediment, SRM 1547 Peach Leaves, SRM 2780 Hard Rock Mine Waste, and SRM 2711 Montana Soil were used in this testing program. Samples were irradiated in the rabbit system facility with fluks neutron thermal 1013 n.cm-2.det-1 for 5 – 10 minutes. The result of accuration and precision parameters testing gave good result for quantified elements depend on the matrix samples. On the accuration and precision testing for As gave bad result. But generally this method is applicable for testing method in AAN laboratory.
Key words: neutron activation analysis, precision, accuration, standard reference material
Item Type: | Conference or Workshop Item (Paper) |
---|---|
Subjects: | Taksonomi BATAN > Reaktor Nuklir > Pemanfaatan Reaktor > Teknologi Berkas Neutron Taksonomi BATAN > Reaktor Nuklir > Pemanfaatan Reaktor > Teknologi Berkas Neutron |
Divisions: | BATAN > Pusat Reaktor Serba Guna IPTEK > BATAN > Pusat Reaktor Serba Guna |
Depositing User: | Administrator Repository |
Date Deposited: | 11 Feb 2019 06:50 |
Last Modified: | 31 May 2022 03:42 |
URI: | https://karya.brin.go.id/id/eprint/8632 |