ANALISIS KECENDERUNGAN PRESISI DAN AKURASI METODE k0-AAN UNTUK BAHAN ACUAN. Analisis kecenderungan presisi dan akurasi metode k0-AAN dapat ditentukan dari eksperimen untuk perhitungan besarnya penyimpangan hasil analisis , yaitu: perhitungan nilai bias, akurasi dan presisi setiap unsur yang terkandung dalam cuplikan. Dalam eksperimen ini dilakukan analisis cuplikan SRM 1648 untuk mengetahui kecenderungan presisi dan akurasi metode yang diterapkan. Unsur-unsur yang dapat dianalisis antara lain: Na, Zn, Cl (grafik 1), Co, Sc, Sb, Sm (grafik 2), Br, Ba,Cr, As dan V (grafik 3). Hasil analisis dicapai dengan nilai bias < 10 %, kecuali untuk Na diperoleh dengan nilai bias > 14 %. Dan hasil analisis juga dicapai dengan tingkat akurasi yang baik kecuali untuk unsur Ba dicapai dengan tingkat akurasi rendah, sedangkan hasil analisis dicapai dengan tingkat presisi tinggi hanyalah untuk unsur-unsur Sc, Br, Sb, Ba, dan V dan untuk unsur-unsur yang lain dicapai dengan tingkat presisi rendah.

Kata kunci: metode k0-AAN, bias, akurasi, presisi

ABSTRACT

A TENDENCY ANALYSIS OF A PRECISION AND ACCURACY OF k0-NAA METHOD FOR A REFERENCE MATERIAL A tendency analysis of a precision and accuracy of k0-NAA method could determine by experiment for calculate a bias of analysis results, namely: a calculation of bias and accuracy and precision values of each element in a sample. In this experiment performed an analysis of SRM 1648 to know a tendency of precision and accuracy of the application method. The elements it could analysis, namely: Na, Zn, Cl (chart 1), Co, Sc, Sb, Sm (chart 2), Br, Ba, Cr, As and v (chart 3). An analysis results attained with a bias values of < 10 %, except for Na attained with a bias value of > 14 %. And an analysis results also attained with a good accuracy level except for Ba attained with a low accuracy, while an analysis results attained with a high precision level only for Sc, Br, Sb, Ba and V elements and for others attained with a low precisions.

Key word : k0-NAA, bias, accuracy, precision.

Item Type: Conference or Workshop Item (Paper)
Subjects: Taksonomi BATAN > Reaktor Nuklir > Operasi dan Pemeliharaan Reaktor > Operasi
Taksonomi BATAN > Reaktor Nuklir > Operasi dan Pemeliharaan Reaktor > Operasi
Divisions: BATAN > Pusat Reaktor Serba Guna
IPTEK > BATAN > Pusat Reaktor Serba Guna
Depositing User: Administrator Repository
Date Deposited: 11 Feb 2019 05:08
Last Modified: 31 May 2022 03:42
URI: https://karya.brin.go.id/id/eprint/8627

Actions (login required)

View Item
View Item