PENGEMBANGAN SISTEM DIAGNOSIS TERAS REAKTOR RSG GAS

Syaiful Bakhri, SB (2006) PENGEMBANGAN SISTEM DIAGNOSIS TERAS REAKTOR RSG GAS. In: PROSIDING HASIL PENELITIAN PRSG.

[thumbnail of 14syaiful.pdf]
Preview
Text
14syaiful.pdf

Download (310kB) | Preview

Abstract

PENGEMBANGAN SISTEM DIAGNOSIS TERAS REAKTOR RSG GAS. Telah dilakukan pengembangan sistem diagnosis teras reaktor RSG GAS menggunakan perangkat lunak labview. Penelitian dilakukan mengingat pentingnya perawatan prediktif sistem pendingin dengan menggunakan analisis diagnosis. Perangkat sistem pemantauan yang sudah ada masih perlu ditingkatkan karena hanya bisa mengamati parameter-parameter overall saja dan masih berupa sistem analog meter biasa. Penelitian dilakukan dengan merangkai dan menyusun koneksi perangkat keras, membuat perangkat lunak, menguji dan mengaplikasikannya pada teras reaktor RSG GAS. Perangkat keras meggunakan digital signal analyzer NI-4551, accelerometer dan perangkat lunak Labview Profesional development system 8.2 terlisensi. Pengujian dan karakterisasi menunjukkan bahwa sistem dapat berfungsi dengan baik sebagai signal analyzer. Respon input frekuensi 0.446 dengan rentang dinamis lebih dari 90 db. Selain itu aplikasi pengukuran terhadap teras reaktor juga telah memberikan hasil spektrum FFT yang dapat menjelaskan fenomena sistem. Untuk aplikasi pengukuran lebih teliti, sistem masih perlu dikembangkan karena resolusi frekuensi yang masih rendah.

ABSTRACT

DEVELOPMENT OF DIAGNOSTIC SYSTEM OF THE RSG GAS REACTOR CORE. The development of diagnostic system for RSG-GAS reactor core, has been done. Research was done considering important of predictive maintenance cooling system. Device of monitoring systems that used before require to be improved because it’s only provided overall parameters and an old analogous meter systems. Research was done by arranging hardware, making software, testing and implementing this system at reactor core of RSG GAS. In this research, hardware using NI-4551 digital signal analyze, accelerometer, and software using Labview Profesional development system Edition 8.2 licensed. Examination and characterization indicate that the systems functioning well as signal analyzer. Input frequency Response is 0.446 and dynamic range more than 90 db. Besides that, measurement application to reactor core has also given FFT spectrum result that able to explain of reactor corecharacteristic. For more accurate measurement applications, systems require to be developed because frequency resolution which still lower.

Item Type: Conference or Workshop Item (Paper)
Subjects: Taksonomi BATAN > Reaktor Nuklir > Teknologi Reaktor > Sistem Reaktor
Taksonomi BATAN > Reaktor Nuklir > Teknologi Reaktor > Sistem Reaktor
Divisions: BATAN > Pusat Reaktor Serba Guna
IPTEK > BATAN > Pusat Reaktor Serba Guna
Depositing User: Administrator Repository
Date Deposited: 11 Feb 2019 04:54
Last Modified: 31 May 2022 03:42
URI: https://karya.brin.go.id/id/eprint/8621