MENENTUKAN KANDUNGAN PENGOTOR DALAM VIAL POLIETILEN DAN QUARTZ DENGAN METODE ANALISIS AKTIVASI NEUTRON

Ratnawati, Elisabeth and Sunarko, Sunarko and Saleh Hartaman, SH (2006) MENENTUKAN KANDUNGAN PENGOTOR DALAM VIAL POLIETILEN DAN QUARTZ DENGAN METODE ANALISIS AKTIVASI NEUTRON. In: PROSIDING HASIL PENELITIAN PRSG.

[thumbnail of 4betty.pdf]
Preview
Text
4betty.pdf

Download (273kB) | Preview

Abstract

MENENTUKAN KANDUNGAN PENGOTOR DALAM VIAL POLIETILEN DAN QUARTZ DENGAN METODE ANALISIS AKTIVASI NEUTRON. Telah dilakukan pengukuran kandungan pengotor dalam vial polietilen dan quartz dengan metode analisis aktivasi neutron di PRSG. Pengukuran kandungan pengotor ini dilakukan untuk menentukan kemurnian vial yang akan berpengaruh terhadap hasil analisis. Dari pengukuran yang dilakukan diperoleh hasil sebagai berikut, untuk vial jenis polietilen terdapat pengotor yang terdiri dari unsur Lanthanim dan Chromium masing-masing dengan konsentrasi 0.0958 ± 0.022 µg/gr dan 0.2570 ± 0.116 µg/gr. Sedangkan pada vial jenis quartz terdapat pengotor yang terdiri dari unsur chromium dengan konsentrasi 1.0955 ± 0.691 µg/gr. Dengan diketahuinya jenis pengotor yang terdapat pada vial, diharapkan dapat digunakan sebagai pendukung dalam pencapaian hasil analisis sampel dengan metode AAN yang memiliki tingkat akurasi tinggi.

Kata kunci: Vial, pengotor

ABSRACT

DETERMINING POLLUTANT CONTENT IN POLIETILEN VIAL AND QUARTZ WITH NEUTRON ACTIVATION ANALYSIS METHOD. The measurement of pollutant content of polyethylene vial and quartz with neutron activation analysis method has been conducted in PRSG. The measurement of this pollutant content is done to determine of the vial clean which is have a fluence on to result of analysis. From the measurement done was obtained the following result, for the vial of polyethylene type there are pollutant which consist of Lanthanim element and Chromium with concentration each 0.0958 ± 0.022 µ g / gr and 0.2570 ± 0.116 µ g / gr. While at the quartz vial type there are pollutant which consist of element of chromium with concentration 1.0955 ± 0.691 µ g / gr. By known of the pollutant type which is found on the vial, it is expected can be used as a supporter in attainment of the sample analyze result by the AAN method which is owning high accuration level

Key words : Vial, pollutant

Item Type: Conference or Workshop Item (Paper)
Subjects: Taksonomi BATAN > Keselamatan dan Keamanan Nuklir > Keselamatan Lingkungan > Analisis Mengenai Dampak Lingkungan
Taksonomi BATAN > Keselamatan dan Keamanan Nuklir > Keselamatan Lingkungan > Analisis Mengenai Dampak Lingkungan
Divisions: BATAN > Pusat Reaktor Serba Guna
IPTEK > BATAN > Pusat Reaktor Serba Guna
Depositing User: Administrator Repository
Date Deposited: 11 Feb 2019 04:03
Last Modified: 31 May 2022 03:42
URI: https://karya.brin.go.id/id/eprint/8605

Actions (login required)

View Item
View Item