KAJIAN PERBAIKAN MUTU DAYA LISTRIK RSG-GAS

Yan Bony Marsahala, YBM (2005) KAJIAN PERBAIKAN MUTU DAYA LISTRIK RSG-GAS. Buletin "Reaktor". ISSN ISSN: 0216-2695

[thumbnail of 3- Yan Bony-oke [109-121].pdf]
Preview
Text
3- Yan Bony-oke [109-121].pdf

Download (577kB) | Preview

Abstract

KAJIAN PERBAIKAN MUTU DAYA LISTRIK RSG-GAS. Kajian perbaikan mutu daya listrik dimaksud dalam tulisan ini merupakan pembahasan karakteristik listrik yang difokuskan pada bentuk gelombang tegangan yang fluktuatif akibat dari pengaruh sambaran petir secara langsung maupun tidak langsung pada instalasi nuklir RSG-GAS. Dalam keadaan normal (tidak ada gangguan sambaran petir) dilakukan pengukuran bentuk gelombang tegangan pada busbar BHA dengan menggunakan power line monitor. Hasil yang diperoleh menunjukkan bahwa bentuk gelombang tegangan berbentuk gelombang sinus. Peralatan tersebut di atas kemudian dipasang secara kontinu untuk menangkap karakeristik bentuk gelombang tegangan pada saat terjadi sambaran petir. Pengaruh sambaran petir pada jaringang listrik dapat dilihat dari rekaman alat tersebut yang menunjukkan bahwa bentuk gelombang tegangan mengalami perubahan. Untuk memperbaiki bentuk gelombang tegangan maka selanjutnya digunakan lightning arrester, dan over voltage arrester yang ditempatkan pada busbar BHA02. Alat tersebut diharapkan dapat memberbaiki bentuk gelombang tegangan yang rusak kembali kebentuk normal.

Kata kunci: mutu daya

ABSTRACT
STUDY FOR ELECTRIC POWER IMPROVEMENT OF RSG-GAS. Study for electric power improvement means that discussion for characteristics of electricity focused at the fluctuation of voltage waveforms caused by influence of lightning attack both directly or indirectly to RAG-GAS nuclear installation. The measuring BHA bus bar voltage waveform by used power line monitor will be done at normal conditions (there’s no lightning attacks). The measuring result shows that the voltage waveform is sinusoidal. The measuring devices as describe above will be installs for continuous measuring to get voltage waveform in the case of lightning attack occurs. The influence of lightning attack into power line can be read from that device recording which show that the voltage waveform have changed. In order to recovery the voltage waveform can be done by used the lightning arrester, and over voltage arrester that installed at bus bar BHA-02. That device will be hoped could overcome the damage of waveform to normal condition.

Keyword: power quality

Item Type: Article
Subjects: Taksonomi BATAN > Reaktor Nuklir > Teknologi Reaktor > Instrumentasi dan Kendali Reaktor
Taksonomi BATAN > Reaktor Nuklir > Teknologi Reaktor > Instrumentasi dan Kendali Reaktor
Divisions: BATAN > Pusat Reaktor Serba Guna
IPTEK > BATAN > Pusat Reaktor Serba Guna
Depositing User: Administrator Repository
Date Deposited: 04 Feb 2019 02:40
Last Modified: 31 May 2022 03:46
URI: https://karya.brin.go.id/id/eprint/8537

Actions (login required)

View Item
View Item