ANALISIS PENGOPERASIAN REAKTOR RSG-GAS PADA TERAS 96 DENGAN DAYA MAKSIMUM 30 MW.

Sukiyanto, Sukiyanto and Susanto, susanto (2018) ANALISIS PENGOPERASIAN REAKTOR RSG-GAS PADA TERAS 96 DENGAN DAYA MAKSIMUM 30 MW. Buletin "Reaktor". ISSN ISSN: 0216-2695

[thumbnail of SUKIY.pdf]
Preview
Text
SUKIY.pdf

Download (392kB) | Preview

Abstract

ANALISIS PENGOPERASIAN REAKTOR RSG-GAS PADA TERAS 96 DENGAN DAYA MAKSIMUM 30 MW. Reaktor RSG-GAS merupakan reaktor riset dengan daya nominal 30 MW termal yang digunakan untuk kegiatan penelitian, iradiasi, pendidikan dan pelatihan.Reaktor RSG-GAS dioperasikan rutin hanya pada daya 15 MW, sedangkan operasi reaktor dengan daya maksimum 30 MW dilakukan dalam waktu tertentu sesuai permintaan dan persetujuan dari BAPETEN (sebagai badan pengawas). Pengoperasian reaktor RSG-GAS pada teras 92 dengan daya maksimum 30 MW ada perbedaan/ ketidaksesuaian antara daya yang dikehendaki (30 MW) dengan daya aktual (28,008 MW). Pengoperasian reaktor RSG-GAS pada teras 96 dengan daya 30 MW dilakukan kalibrasi daya reaktor kemudian hasilnya dibandingkan dengan daya yang dikehendaki. Hasil kalibrasi daya reaktor untuk pengoperasian daya 30 MW adalah sebesar 30,040 MW. Hasil perbandingan antara daya aktual / hasil kalibrasi dengan daya yang dikehendaki hampir sama. Hal tersebut menunjukan terjadi kesesuaian pengoperasian reaktor RSG-GAS pada teras 96 dengan daya maksimum 30 MW.

Kata kunci : Reaktor RSG-GAS, Operasi Reaktor, Kalibrasi Daya, .

ABSTRACT

ANALYSIS OF OPERATING THE RSG-GAS REACTOR ON THE CORE 96 WITH A MAXIMUM POWER OF 30 MW. The RSG-GAS reactor is a research reactor with a nominal power of 30 MW thermal that is used for research, irradiation, education and training activities. The RSG-GAS reactor is operated routinely only at 15 MW of power, while reactor is in operation with a maximum power of 30 MW carried out within a certain time on request and approval from BAPETEN (as the regulatory body). In the RSG-GAS reactor operation of the core 92 with a maximum power of 30 MW therewas a difference / discrepancy between the desired power (30 MW) and the actual power (28,008 MW)[13]. In the RSG-GAS reactor operation of the core 96 with a power of 30 MW the reactor power calibration was carried out then the results compared with the desired power. The results of the reactor power calibration for the operation of 30 MW of power is 30,040 MW. The results of the comparison between the actual power / calibration results with the desired power is almost the same. This shows that there is a suitability for the operation of the RSG-GAS reactor on core 96 with a maximum power of 30 MW.

Keywords : RSG-GAS Reactor, Reactor Operation, Power Calibration.

Item Type: Article
Subjects: Taksonomi BATAN > Reaktor Nuklir > Operasi dan Pemeliharaan Reaktor > Operasi
Taksonomi BATAN > Reaktor Nuklir > Operasi dan Pemeliharaan Reaktor > Operasi
Divisions: BATAN > Pusat Reaktor Serba Guna
IPTEK > BATAN > Pusat Reaktor Serba Guna
Depositing User: Administrator Repository
Date Deposited: 29 Jan 2019 03:48
Last Modified: 02 Jun 2022 03:17
URI: https://karya.brin.go.id/id/eprint/8483

Actions (login required)

View Item
View Item