Abstract
ABSTRAK
EVALUASI PARAMETER NEUTRON KASIP REAKTOR PWR AP1000. Laju perubahan
neutron selama manuver batang kendali sangat ditentukan oleh parameter neutron kasip. Oleh
karena itu evaluasi parameter neutron kasip untuk PLTN PWR Generasi-III+, seperti reaktor
AP1000, perlu dilakukan untuk mengetahui peningkatan keselamatan yang telah dilakukan desainer.
Tujuan penelitian ini untuk mengetahui karakteristik parameter neutron kasip reaktor AP1000 untuk
kondisi cold zero power (dengan dan tanpa boron) dan hot zero power (dengan dan tanpa boron).
Perhitungan parameter neutron kasip dilakukan dengan paket program metode difusi neutron 3-
dimensi BATAN-3DIFF untuk 2, 4 dan 10 kelompok tenaga neutron. Perhitungan sel untuk
generasi konstanta difusi dilakukan dengan paket program SRAC2006. Data neutron kasip dari
Keepin, Tuttle dan Brady-England dipakai dalam penelitian ini. Hasil perhitungan menunjukkan
harga fraksi neutron kasip efektif dengan data Brady-England memberikan hasil yang paling dekat
dengan nilai desain dengan perbedaan 1,48%. Sedangkan untuk parameter umur hidup neutron
rerata, perbedaan dengan desain 3,50%. Hasil penelitian menunjukkan bahwa reaktor AP1000
memiliki kestabilan yang relatif konstan meskipun konsentrasi boron dan temperatur berubah.
Kata kunci: PWR, fraksi neutron kasip efektif, umur hidup neutron rerata, BATAN-3DIFF,
SRAC2006
ABSTRACT
THE EVALUATION OF DELAY NEUTRON PARAMETERS IN THE AP1000 PWR
REACTOR. The rate of change of the neutron population during control rods maneuver is
determined by the delayed neutron. Therefore, the evaluation delayed neutron parameters for the
PWR Generation-III+ reactor, such as the AP1000 reactor, should be carried out to evaluate the
safety improvement has been prepared by designer. The purpose of this study to determine the
characteristic of the delayed neutron parameters for the AP1000 reactor in the cold zero power
condition (with and without boron) and the hot zero power (with and without boron). The delayed
neutron parameters calculation were carried out by using the 3-dimensional neutron diffusion
method code, BATAN-3DIFF, for 2, 4 and 10 neutron energy groups. The cell calculations for
generating the neutron diffusion group constants were carried out by using the SRAC2006 code.
The delayed neutron data from Keepin, Tuttle and Brady-England were used in this study. The
calculation results show that the effective delayed neutron fraction using Brady-England data is very
close to the design value with a difference of 1.48%. Then, the calculated average neutron life time
has a difference of 3.50% compared to design value. The results showed that the AP1000 reactor
has a constant relative stability, although the boron concentration and temperature are changed.
Keywords: PWR, effective delayed neutron fraction, average neutron life time, BATAN-3DIFF,
SRAC2006
Item Type: | Article |
---|---|
Subjects: | Taksonomi BATAN > Keselamatan dan Keamanan Nuklir Taksonomi BATAN > Keselamatan dan Keamanan Nuklir |
Divisions: | BATAN > Pusat Teknologi dan Keselamatan Reaktor Nuklir IPTEK > BATAN > Pusat Teknologi dan Keselamatan Reaktor Nuklir |
Depositing User: | Administrator Repository |
Date Deposited: | 13 Nov 2018 04:17 |
Last Modified: | 31 May 2022 09:23 |
URI: | https://karya.brin.go.id/id/eprint/4988 |