VERIFIKASI MODEL PERANGKAT BAHAN BAKAR REAKTOR DAYA PWR-1000

Sukmanto Dibyo, SD (2011) VERIFIKASI MODEL PERANGKAT BAHAN BAKAR REAKTOR DAYA PWR-1000. VERIFIKASI MODEL PERANGKAT BAHAN BAKAR REAKTOR DAYA PWR-1000. pp. 385-395. ISSN 0854-2910

[thumbnail of 27_Sukmanto Dibyo dkk-PTRKN-cd.pdf]
Preview
Text
27_Sukmanto Dibyo dkk-PTRKN-cd.pdf

Download (249kB) | Preview

Abstract

ABSTRAK
VERIFIKASI MODEL PERANGKAT BAHAN BAKAR REAKTOR DAYA PWR-1000.
Aanalisis verifikasi model termohidrolika perangkat bahan bakar berguna untuk mengetahui
karakteristik desain termohidrolika teras reaktor. Paket program RELAP5 berhasil memodelkan satu
perangkat bahan bakar dan diverifikasi dengan data desain. Data desain dari reaktor daya AP1000
digunakan sebagai data referensi. Pada perangkat bahan bakar ini terdapat 17x17 batang yang
memiliki faktor daya yang bervariasi. Pemodelan membagi perangkat menjadi 4 kelompok kanal
yaitu kelompok faktor daya 1,396, faktor daya rentang 1,203 sampai 1,394, rentang 1,198 kebawah
dan kanal bypass. Secara aksial, perangkat dibagi menjadi 3 zona yaitu zona stand-off assembly di
bagian bawah, zona panjang aktif dan zona plenum atas. Ssedangkan panjang aktif dibagi menjadi
10 node aksial. Hasil verifikasi menunjukkan bahwa model yang dibuat masih perlu penyempurnaan,
namun demikian secara kualitatif berada dalam batas yang realistis. Selanjutnya pemutakhiran model
akan dilakukan untuk mendapatkan hasil verifikasi yang lebih baik.
Kata kunci: Perangkat Bahan Bakar PWR-1000, Pemodelan, Desain Termohidrolika, RELAP5
ABSTRACT
FUEL BUNDEL MODEL VERIFICATION OF PWR-1000 POWER PLANT. Verification
analysis of the fuel thermal-hydraulic model is useful to know the characteristics of the reactor core
thermal-hydraulic design. Package RELAP5 program succeeded in modeling a set of fuel and
verified with design data. Design data on the ap1000 power reactor is used as the references. On the
fuel bundle, there are 17x17 fuel rods that have a radial factor the power varies. Modeling of fuel
bundle are divided into 4 channel groups, ie. Power factor of 1.396, range power factor of 1.203 to
1.394, power factor of less then 1.198 down and bypass channel. Axially, the channel are divided
into 3 zones there are stand-off assembly at the bottom, an active length of the channel and the zone
of upper plenum. Verification results show that the model is made still need refinement, however
qualitatively within realistic limits. Further updating of the model will be done to get a better
verification results.
Keywords: PWR-1000 Fuel Bundle, Modeling, Thermalhydraulic Design, RELAP5

Item Type: Article
Subjects: Taksonomi BATAN > Keselamatan dan Keamanan Nuklir
Taksonomi BATAN > Keselamatan dan Keamanan Nuklir
Divisions: BATAN > Pusat Teknologi dan Keselamatan Reaktor Nuklir
IPTEK > BATAN > Pusat Teknologi dan Keselamatan Reaktor Nuklir
Depositing User: Administrator Repository
Date Deposited: 12 Nov 2018 09:01
Last Modified: 02 Jun 2022 02:24
URI: https://karya.brin.go.id/id/eprint/4965

Actions (login required)

View Item
View Item