KORELASI ANTARA WAKTU PENGADUKAN DAN SEDIMEN ZAT RADIOAKTIF DALAM TANGKI LIMBAH CAIR AKTIVITAS RENDAH RSG-GAS

Rohidi, Rohidi and Anto Setiawanto, AS and Subiharto, Subiharto (2016) KORELASI ANTARA WAKTU PENGADUKAN DAN SEDIMEN ZAT RADIOAKTIF DALAM TANGKI LIMBAH CAIR AKTIVITAS RENDAH RSG-GAS. Prosiding Seminar Nasional Teknologi dan Aplikasi Reaktor Nuklir. ISSN 976-602-6423-00-9

[thumbnail of 27-ROHIDI.pdf]
Preview
Text
27-ROHIDI.pdf

Download (481kB) | Preview

Abstract

KORELASI ANTARA WAKTU PENGADUKAN DAN SEDIMEN ZAT RADIOAKTIF DALAM TANGKI LIMBAH CAIR AKTIVITAS RENDAH RSG-GAS. Limbah cair adalah limbah dalam bentuk larutan atau cairan yang mengandung zat radioaktif terlarut dan merupakan dampak dari kegiatan pengoperasian reaktor. Untuk memenuhi persyaratan pengiriman maka limbah harus dicuplik dan analisis untuk mengetahui nuklida yang terkandung didalamnya. Proses pengambilan sampel pada tangki dilakukan dengan cara pengadukan, untuk mendapatkan waktu yang tepat pada saat pengambilan sampel. Berdasarkan lamanya waktu pengadukan yaitu : 0 menit, 5 menit, 10 menit, 15 menit, 20 menit, 25 menit kemudian dianalisis dengan cara mengamati spektrum karakteristik yang ditimbulkan oleh interaksi radiasi dengan detektor menggunakan alat spektrometer gamma. Dari hasil analisis cuplikan sampel teridentifikasi nuklida Co-60, Zn-65 dan Na-24. Pada proses pengadukan 10 menit terjadi peningkatan nilai aktivitas yang signifikan sehingga ini merupakan waktu yang tepat dan efektif dalam pencuplikan sampel dan semakin lama proses pengadukan maka endapan sedimen zat radioaktif akan terakumulasi didalam tangki
Kata Kunci : Pengadukan, limbah Cair, aktivitas
ABSTRACT
CORRELATION BETWEEN STIRRING TIME and RADIOACTIVE SUBSTANCES IN THE LOW WASTE SOLUTION TANK OF THE RSG-GAS The liquid waste is waste in the form of a solution or liquid containing radioactive substances dissolved and constitute of result of the reactor operation. To meet the delivery requirements, waste should be analysis to recognize of nuclides contained therein. Sampling on the tank is done by stirring the waste solution in order to obtain a right time of sampling. Stirring is done such as: o minutes, 5 minutes, 10 minutes, 15 minutes, 20 minutes and 25 minutes. Then sample is analyzed by observing the spectral characteristics caused by the interaction of radiation with the detector using gamma spectrometer. From the analysis of the sample there are identified several of nuclides such as Co-60, Zn-65 and Na-24. In the process of stirring of 10 minutes it is obvious that activity increased significantly of Co-60 = 37.65 Bq / l, Zn-65 = 10.29 Bq / l and Na = 12,03 Bq/l. Then it is concluded that the right time is 10 minutes to effectively sampling. The more stirring the more deposit occur in the bottom of the storage tank
Key words: stirring, waste solution, activity

Item Type: Article
Subjects: Taksonomi BATAN > Keselamatan dan Keamanan Nuklir > Keselamatan Lingkungan > Analisis Mengenai Dampak Lingkungan
Taksonomi BATAN > Keselamatan dan Keamanan Nuklir > Keselamatan Lingkungan > Analisis Mengenai Dampak Lingkungan
Divisions: BATAN > Pusat Reaktor Serba Guna
IPTEK > BATAN > Pusat Reaktor Serba Guna
Depositing User: Administrator Repository
Date Deposited: 30 Oct 2018 01:23
Last Modified: 31 May 2022 04:45
URI: https://karya.brin.go.id/id/eprint/4156