Sukiyanto, Sukiyanto and Bagus Dwi Nurtanto, BDN (2016) PENGUKURAN FAKTOR KOREKSI KALIBRASI DAYA REAKTOR RSG-GAS. Prosiding Seminar Nasional Teknologi dan Aplikasi Reaktor Nuklir. ISSN 976-602-6423-00-9
23-SUKIYANTO.pdf
Download (336kB) | Preview
Abstract
PENGUKURAN FAKTOR KOREKSI KALIBRASI DAYA REAKTOR RSG-GAS. Kalibrasi daya reaktor adalah proses penyesuaian/ pengaturan ulang alat ukur/ kanal-kanal ukur daya reaktor terhadap besaran/ nilai standar yang telah diketahui. Daya reaktor harus dikoreksi karena hal in menyangkut keselamatan reaktor. Dalam beberapa kali operasi, kalibrasi daya reaktor cenderung mengalami kenaikan, sehingga parameter dan nilai-nilai yang mempengaruhinya perlu dikaji/ dianalisa. Salah satu parameter/ nilai yang mempengaruhi kalibrasi daya reaktor adalah faktor koreksi. Makalah ini bertujuan untuk mengukur faktor koreksi, apakah telah terjadi perubahan. Lingkup yang dibahas meliputi parameter pengoperasian RSG-GAS terkait faktor koreksi dan kalibrasi daya reaktor, serta pengukuran faktor koreksi. Pengukuran faktor koreksi dilakukan dalam kondisi seluruh sistem dioperasikan seperti pada saat operasi daya tinggi. Dari hasil pengukuran diketahui bahwa nilai faktor koreksi mengalami perubahan dari 0,17 menjadi 0,41. Perubahan tersebut berpengaruh terhadap hasil kalibrasi daya reaktor serta berpengaruh terhadap perhitungan burn-up bahan bakar. Diharapkan hasil pengukuran ini dapat digunakan sebagai salah satu acuan dalam melakukan kalibrasi daya reaktor RSG-GAS dan sebagai bahan pertimbangan agar dilakukan pengukuran faktor koreksi secara berkala.
Kata kunci: reaktor RSG-GAS, kalibrasi daya reaktor, faktor koreksi.
ABSTRACT
MEASUREMENT OF THE CORRECTION FACTOR FOR POWER CALIBRATION OF THE RGS-GAS REACTOR. The reactor power calibration is the process of adjusting/ reorganizing gauge/ canals measuring reactor power to the magnitude or default values that has been known. The reactor power should be corrected due to it relate t safety of the reactor. Several times in the operation, calibration of reactor power tends to increase causing all parameter of power reactor need to be reviewed. One of the parameters that affect the reactor power calibration is a correction factor. This paper is aimed to measure of correction factor whether it is changed. The scope covered includes such as the parameter of operation of the RSG-GAS relate to correction factor and power calibration factor. The correction factor measurement is carried out in conditions of the entire system is operated as during high power operation. From the measurement it has been recognized that the correction factor changes from 0,17 to 0,41. The changes also affect the reactor power calibration results and the calculation of fuel burn-up either. It is expected that result of the measurement can be used as a reference in reactor power calibration of the RSG-GAS to conduct correction factor measurements periodically
Key words: RSG-GAS reactor, reactor power calibration, correction factor.
Item Type: | Article |
---|---|
Subjects: | Taksonomi BATAN > Reaktor Nuklir > Operasi dan Pemeliharaan Reaktor > Operasi Taksonomi BATAN > Reaktor Nuklir > Operasi dan Pemeliharaan Reaktor > Operasi |
Divisions: | BATAN > Pusat Reaktor Serba Guna IPTEK > BATAN > Pusat Reaktor Serba Guna |
Depositing User: | Administrator Repository |
Date Deposited: | 30 Oct 2018 01:08 |
Last Modified: | 31 May 2022 04:46 |
URI: | https://karya.brin.go.id/id/eprint/4150 |