MODIFIKASI MODUL AMPLIFIER KANAL PENGUKURAN JKT03 CX821

Prijanto, Heri and Heri Suherkiman, HS and Edison, Edison (2016) MODIFIKASI MODUL AMPLIFIER KANAL PENGUKURAN JKT03 CX821. Prosiding Seminar Nasional Teknologi dan Aplikasi Reaktor Nuklir. ISSN 976-602-6423-00-9

[thumbnail of 14A-HARI P.pdf]
Preview
Text
14A-HARI P.pdf

Download (899kB) | Preview

Abstract

MODIFIKASI MODUL AMPLIFIER KANAL PENGUKURAN JKT03 CX821. Telah dilakukan modifikasi modul amplifier kanal pengukuran JKT03 CX821 untuk mengembalikan fungsi sistem pengukuran fluks neutron pada daerah daya sebagaimana desainnya. Modifikasi didasarkan pada pengukuran fluks neutron menggunakan metode foil emas yang didapat hasil bahwa kondisi fluks neutron di teras RSG-GAS masih setimbang. Metode lain adalah dengan melakukan pengukuran arus detektor secara langsung menggunakan picoammeter untuk mengetahui linieritas arus keluaran detektor terhadap rentang daya 0 sampai 30 mega watt. Sebelum modifikasi, pengukuran fluks neutron pada kanal JKT03 CX821 mulai respon setelah detektor ditarik kurang lebih 1 meter dari posisi bawah. Setelah modifikasi dengan menambahkan resistor 10 kilo ohm pada modul amplifier dan dilakukan kalibrasi dengan pengaturan potensiometer, penunjukan kanal pengukuran JKT03 CX821 respon pada posisi bawah dan setimbang dengan penunjukkan kanal lainnya (JKT03 CX811/831/841).
Kata kunci : Modifikasi, Modul Amplifier
ABSTRACT
MODIFICATION OF THE AMPLIFIER MODULE FOR JKT03 CX821 MEASURING CHANNEL Modification of the amplifier module for JKT03 CX821 measuring channel has been done to restore the function of the neutron fluxs measuring system in the power range as the design. Modification are based on neutron flux measurement using gold foil that got conditions of the neutron flux in the RSG-GAS’s core is still balanced. Another Method is by measuring detector currents directly using picoammeter to determine the linierity of the output current detector to the power range of 0 to 30 mega watt. Before modification, the channel of the JKT03 CX821 can not measure the neutron flux in the power range without withdrawal of the neutron detector approximately 1 meter from the bottom position. After modification by adding a 10 kilo ohm resistor at the amplifier module and calibration with potentiometer setting, measurement channel JKT03 CX821 response at down position and balance with another channels (JKT03 CX811 / 831/841).
Keywords : Modification, Amplifier Module

Item Type: Article
Subjects: Taksonomi BATAN > Reaktor Nuklir > Teknologi Reaktor > Sistem Reaktor
Taksonomi BATAN > Reaktor Nuklir > Teknologi Reaktor > Sistem Reaktor
Divisions: BATAN > Pusat Reaktor Serba Guna
IPTEK > BATAN > Pusat Reaktor Serba Guna
Depositing User: Administrator Repository
Date Deposited: 29 Oct 2018 07:35
Last Modified: 31 May 2022 04:45
URI: https://karya.brin.go.id/id/eprint/4126

Actions (login required)

View Item
View Item