KALIBRASI DAYA REACTOR TERAS 87 REAKTOR RSG-GAS. Selama pengoperasian reaktor, operator reactor hanya berpedoman pada kanal pengukuran daya yang merupakan system pengukuran fluks neutron. Apabila terjadi perubahan konfigurasi teras reaktor, maka akan terjadi pula perubahan distribusi fluks neutron di teras. Karena detektor-detektor neutron dipasang secara tetap di seputar teras reaktor, maka perubahan distribusi fluks neutron tersebut akan mempengaruhi pula hasil pengukuran sistem pengukuran fluks neutron. Untuk menjamin kebenaran penunjukan kanal pengukuran sistem pengukuran daya reaktor, harus dilakukan kalibrasi daya secara periodik. Tulisan ini mengupas kalibrasi daya dilakukan dengan cara mengukur suhu air pendingin primer pada posisi sebelum dan sesudah penukar panas sehingga diperoleh nilai perbedaan suhu. Perbedaan suhu tersebut digunakan untuk menghitung daya sesungguhnya yang dibangkitkan oleh teras reactor dengan mengetahui laju alir dan kapasitas air pendingin. Daya sesungguhnya yang diperoleh dari kalibrasi digunakan sebagai pedoman untuk melakukan pengesetan nilai pengukur daya reaktor agar detector mengindikasikan daya yang benar. Dengan dilakukan kalibrasi daya reactor secara periodik, maka penunjukan kanal pengukuran daya reactor selalu dapat disesuaikan dengan nilai daya yang sesungguhnya, oleh sebab itu pengendalian daya reaktor yang dibangkitkan di teras reactor dapat dilakukan dengan tepat dan benar.
Kata kunci: pengukuran, pengendalian, fluks neutron
ABSTRACT POWER CALIBRATION OF THE 87TH G.A SIWABESSY REACTOR. During the operation of the reactor, the reactor operators only based on a channel power measurement which is a neutron flux measurement system. In the event of changes in the configuration of the reactor core, there will be also changes the distribution of neutron flux on the core. Because neutron detectors permanently installed around the reactor core, the neutron flux distribution changes will influence the measurement results of neutron flux measurement system. To guarantee correctness measurement channel designation reactor power measurement system, power calibration should be performed periodically. Power calibration is done by measuring the temperature of the primary cooling water at the position before and after the heat exchanger in order to obtain the value of the temperature difference. The temperature difference is used to calculate the actual power generated by the reactor core to determine flow rate and capacity of cooling water. Actual power obtained from calibration is used as a guideline for setting the value of measuring the power of the reactor so that the detector indicates the correct power. With reactor power calibration performed on a periodic basis, the appointment of reactor power measurement channels can always be adjusted to the value of the real power. Thus, the reactor power control generated in the reactor core can be done properly and correctly.
Keywords: measurement, controlling, fluks neutron

Item Type: Article
Subjects: Taksonomi BATAN > Reaktor Nuklir > Operasi dan Pemeliharaan Reaktor > Operasi
Taksonomi BATAN > Reaktor Nuklir > Operasi dan Pemeliharaan Reaktor > Operasi
Divisions: BATAN > Pusat Reaktor Serba Guna
IPTEK > BATAN > Pusat Reaktor Serba Guna
Depositing User: Administrator Repository
Date Deposited: 29 Oct 2018 03:15
Last Modified: 31 May 2022 04:54
URI: https://karya.brin.go.id/id/eprint/4081

Actions (login required)

View Item
View Item