UJI AKURASI ALAT PENCACAH SPEKTROMETER GAMMA DENGAN MENGGUNAKAN SUMBER STANDAR

Ratnawati, Elisabeth and Jaka Iman, JI (2015) UJI AKURASI ALAT PENCACAH SPEKTROMETER GAMMA DENGAN MENGGUNAKAN SUMBER STANDAR. PROSIDING SEMINAR NASIONAL TEKNOLOGI DAN APLIKASI REAKTOR NUKLIR. ISSN 978-979-8500-67-1

[thumbnail of 5-Betty 23-28.pdf]
Preview
Text
5-Betty 23-28.pdf

Download (762kB) | Preview

Abstract

UJI AKURASI ALAT PENCACAH SPEKTROSMETER GAMMA DENGAN MENGGUNAKAN SUMBER STANDAR. Setelah digunakan sekian lama maka perlu untuk mengetahui apakah alat pencacah spektrometer gamma milik Bidang Operasi Reaktor masih memiliki kinerja seperti yang diharapkan. Karena itu akan dilakukan uji akurasi alat pencacah dengan menggunakan sumber standar titik yaitu Ba-133, Cs-137 dan Co-60. Dimana sumber standar ini dapat mewakili energi rendah, menengah dan energi tinggi. Uji akurasi dilakukan dengan cara menghitung aktivitas ketiga sumber standar titik yang difungsikan sebagai sampel/analit. Untuk mendapatkan nilai aktivitas maka dilakukan pencacahan sampel/analit selama 7200 detik dengan pengulangan masing masing sampel sebanyak lima kali. Sebagai sumber standar acuan digunakan sumber titik Eu-152 yang dicacah selama 10.000 detik untuk memperoleh nilai efisiensi pada energi tertentu. Hasil perhitungan aktivitas ketiga analit kemudian dibandingkan dengan nilai yang tertera dalam sertifikat, pada tanggal yang sama. Berdasarkan hasil uji akurasi diketahui bahwa hanya Ba-133 yang dinyatakan lolos/diterima, sedangkan Cs-137 dan C0-60 dinyatakan tidak lolos. Sedangkan dari perhitungan indeks bias relatif untuk sumber standar Ba-133 adalah sebesar -0,92%, sumber standar Cs-137 sebesar -12,60%, dan Co-60 sebesar -9,53%. Perbedaan nilai hasil uji dengan nilai yang tertera pada sertifikat dapat disebabkan oleh banyak faktor, diantaranya faktor kesalahan/eror pada saat pencacahan, faktor kesalaha pada manusia, maupun dari peralatan itu sendiri. Perlu dilakukan percobaan lanjutan serta pengecekan kembali terhadap rangkaian alat pencacah ini agar kinerjanya terus terjaga dan stabil, terutama pada pencacahan nuklida dengan energi menengah dan energi tinggi, sehingga untuk selanjutnya dapat memberikan hasil analisis yang lebih akurat serta dapat dipercaya.
Kata kunci: akurasi, sumber standar, gamma spektrometer
THE ACCURACY TEST FOR GAMMA SPECTROMETER SYSTEM USING STANDARD SOURCES. After have been used for such a long time, it is necessary to determine whether PRSG's gamma spectrometer system is still performing as expected or not. THEREFORE the accuracy test should be done to the counting EQUIPMENT/tool/system using point standard sources namely Ba-133, Cs-137 and Co-60. These standard sources of energy may represent
low, medium and high energy. Accuracy test is done by calculating those activity of the three standard point source which functioned as a sample / analyte. in order To get the value of the activities, the counting is carried out on the sample / analyte during 7200 seconds with five time repetitions of each samples. Eu-152 is used As a source of reference standards source points, which is counted for 10.000 seconds to earn energy efficiency in particular. the calculation results of Those three activities of the analyte are then compared with the value stated in the certificate, on the same date. Based on the test accuracy results, it is known that only Ba-133 which passed / received, while Cs-137 and C0-60 otherwise not qualified. While from the calculation of the relative refractive index to a standard source of Ba-133 is equal to -0.92%, the standard source of Cs-137 at -12.60%, and Co-60 amounted to -9.53%. The difference between test results value and the standard value stated on the certificate can be caused by many factors, including mistake / error factors while counting, human error factor, as well as of the equipment itself. Further experiments need to be done as well as checking back to the counting tool circuit in order to maintain its performance stability, especially when doing the counting of nuclides with medium energy and high energy, so in the future
this tool is expected to provide a more accurate and trustworthy analysis results .
keyword : accuracy, standard source, gamma spectrometer system

Item Type: Article
Subjects: Taksonomi BATAN > Reaktor Nuklir > Teknologi Reaktor > Instrumentasi dan Kendali Reaktor
Taksonomi BATAN > Reaktor Nuklir > Teknologi Reaktor > Instrumentasi dan Kendali Reaktor
Divisions: BATAN > Pusat Reaktor Serba Guna
IPTEK > BATAN > Pusat Reaktor Serba Guna
Depositing User: Administrator Repository
Date Deposited: 29 Oct 2018 03:09
Last Modified: 31 May 2022 04:54
URI: https://karya.brin.go.id/id/eprint/4080

Actions (login required)

View Item
View Item