ABSTRAK
RANCANGAN ALAT BANTU PENGIRIM KAPSUL PADA SISTEM PNEUMATIC RABBIT DI
REAKTOS RSG-GAS. Salah satu fokus kegiatan pengembangan utilisasi reaktor adalah perancangan alat
bantu pengirim kapsul pneumatic rabbit pasca iradiasi yang berada di RSG-GAS. Alat bantu pengirim kapsul pneumatic rabbit pasca iradiasi ini diperlukan untuk mempercepat pemindahan kapsul pasca iradiasi dari Isotope Cell ke tempat pencacah. Untuk mencapai tujuan tersebut langkah awal yang harus dilakukan adalah perancangan. Rancangan alat bantu transfer kapsul didasarkan pada pertimbangan kepraktisan dan mampu terap. Aspek kepraktisan meliputi penentuan bentuk dan ukuran komponen yang disesuaikan dengan fungsinya. Aspek mampu terap dimaksudkan bahwa kesederhanaan bentuk dan ukuran harus berdampak pada kemudahan bagi operator dalam menangani kapsul pasca iradiasi. Rancangan alatbantu tersebut terdiri dari 2 bagian yaitu bagian komponen di dalam isotope cell dan bagian penghubung dari isotope cell ke tempat pencacah. Material komponen di dalam isotope cell dipilih bahan Aluminium, bahan bagian penghubung dari isotope cell ke tempat pencacah menggunakan pipa plastik berserat kain. Oengan selesainya perancangan ini diharapkan bisa direalisasikan pembuatan alat bantu tersebut, agar system pneumatic rabbit dapat digunakan lebih optimum.

Kata kunci: Rancangan, kapsul, sistem pneumatic rabbit

ABSTRACT
DESIGN OF CAPSULE TRANSFER TOOL FOR PNEUMA TIC RABBIT SYSTEM A T THE RSG-GAS
REACTOR. One of the point interest in development of reactor utilization is design of pneumatic capsule
transfer in rabbit after irradiation in RSG-GAS Reactor. The auxiliary tool of pneumatic capsule transfer in rabbit is needed after irradiation to accelerate the transfer of post irradiation capsules to the enumerator. To achieve these goal is by doing the design. The design of tool based on the practicality and applicability of the capsule transfer. Practicality aspect involves determining the shape and size of the components that can fulfill itsfunction. Applicability aspects meant that the simplicity of the shape size and size have an impact on the convenience to the operator in handling post irradiation capsule. The design of the tool consists of two parts, namely the isoptope component that connects the cell isotopes to the enumerator. Material component parts in isotope cell is used materials by Aluminium. The connecting parts the isotope cell to the counter using fiber hose. With the completion of the design will be expected to produce the tool, that it can optimize the use of pneumatic rabbit system.

Keywords: Design, capsule, pneumatic rabbit system

Item Type: Article
Subjects: Taksonomi BATAN > Reaktor Nuklir > Operasi dan Pemeliharaan Reaktor > Operasi
Taksonomi BATAN > Reaktor Nuklir > Operasi dan Pemeliharaan Reaktor > Operasi
Divisions: BATAN > Pusat Reaktor Serba Guna
IPTEK > BATAN > Pusat Reaktor Serba Guna
Depositing User: Administrator Repository
Date Deposited: 25 Oct 2018 03:29
Last Modified: 31 May 2022 09:23
URI: https://karya.brin.go.id/id/eprint/4049

Actions (login required)

View Item
View Item