PENENTUAN UNSUR KELUMIT UMUR PARa PANJANG DALAM CUPLIKAN LING KUNGAN DENGAN METODE APN

Sri Wardani, SW and Amir Hamzah, AH and Putut Hery Setiawan, PHS and Saleh Hartaman, SH and Rohidi, Rohidi and Jaka Iman, JI (1999) PENENTUAN UNSUR KELUMIT UMUR PARa PANJANG DALAM CUPLIKAN LING KUNGAN DENGAN METODE APN. PROSIDING SEMINAR HASIL PENELITIAN PRSG. ISSN 0854-5278

[thumbnail of Sri Wardani.pdf]
Preview
Text
Sri Wardani.pdf

Download (3MB) | Preview

Abstract

PENENTUAN UNSUR KELUMIT UMUR PARO PANJANG DALAM CUPLIKAN LlNGKUNGAN DENGAN METODE APN. Untuk evaluasi presisi dan akurasi metode Analisis Pengaktipan Neutron (APN ) dan kalibrasi peralatan yang digunakan dalam penelitian dilakukan analisis cuplikan standar referensi daTi NIESJepang untuk cuplikan udara partikulat CRM No.8. Dari hasil analisis cuplikan CRM No.8 memberikan hasil analisis dengan presisi dan akurasi yang baik, pacta deviasi 0,3%-11,4 % dibandingkan nilai analisis daTi sertifikat NIES. Hasil analisis ini menunjukan bahwa metode APN dan peralatan yang digunakan di PRSG cukup andal dan layak untuk analisis berbagai cuplikan lingkungan. Pacta penelitian ini juga dilakukan analisis secara kualitatif dan kuantitatif banyak unsur logam berumur para panjang yang terkandung dalam cuplikan lingkungan sedimen dan air sungai Babon Semarang dengan metode APN. Dari hasil analisis kualitatif cuplikan lingkungan dapat ditentukan banyak unsur, antara lain: La, Sc, Fe, Co, Na, Cr, K, Yb, Eu, Lu, Ce, I, Fa, Cs, Ru, Sm, Hg, As, Mn, Br, Zn, dan Ti. Dan untuk analisis kuantitatif dapat ditentukan konsentrasi dari beberapa unsur logam berbahaya, yaitu: Cr, Co, Fe, Sb, Hg, As, Sc dan La.
ABSTRACT DETERMINATION OF LONG-LIVED TRACE ELEMENTS IN ENVIRONMENT AL SAMPLES BY NEUTRON ACTIVATION ANALYSIS. For evaluation of precision and accuracy of neutron activation analysis method (NAA), and also for calibration of used equipment of this research program performed by analysis a reference standard material of CRM-NIES No.8 of a Vehicle Exhaust Particulate. The resulted analysis of CRM-NIES No.8 sample obtained in a good precision and accuracy, in deviation of 0,3-11,4% compared with NIES-certified values. By this results shown that the method and equipment of PRSG facilities capable to analysis of some kinds of environmental samples. In this research performed in qualitatively and quantitatively analysis of multi elements of long-lived elements in a water and sediment samples of Babon river at Semarang by NAA method. The result of qualitatively analysis were determined multi elements, namely: La, Sc, Fe, Co, Na, Cr, K, Vb, Eu, Lu, Ce, I, Fa, Cs, Ru, Sm, Hg, As, Mn, Br, Zn, and Ti. And the results of quantitatively analysis were determined concentration of few hazard metal elements, namely: Cr, Co, Fe, Sb, Hg, As, Sc and La.

Item Type: Article
Subjects: Taksonomi BATAN > Keselamatan dan Keamanan Nuklir > Keselamatan Lingkungan
Taksonomi BATAN > Keselamatan dan Keamanan Nuklir > Keselamatan Lingkungan
Divisions: BATAN > Pusat Reaktor Serba Guna
IPTEK > BATAN > Pusat Reaktor Serba Guna
Depositing User: Administrator Repository
Date Deposited: 21 Sep 2018 01:56
Last Modified: 02 Jun 2022 02:43
URI: https://karya.brin.go.id/id/eprint/3997

Actions (login required)

View Item
View Item