PERHITUNGAN OPTIlVIASI IRADIASI PRODUK MO99 DI TERASRSG-GASO)

Suroso, S (1999) PERHITUNGAN OPTIlVIASI IRADIASI PRODUK MO99 DI TERASRSG-GASO). PROSIDING SEMINAR HASIL PENELITIAN PRSG. ISSN 0854-5278

[thumbnail of Shidiq S.pdf]
Preview
Text
Shidiq S.pdf

Download (4MB) | Preview

Abstract

PERHITUNGAN OPTIMASI IRADIASI PRODUK MO99DI TERAS RSG-GAS. Perhitungan muatan optimum tiap target penghasil Fission Product Molybdenum (FPM) dilakukan dalam dua aspek yaitu, neutronika dan termohidraulika. Lokasi target masing-masing disekenariokan di posisi Central Irradiation Position (CIP) dan Irradiation Position (IP). Perhitungan daTi aspek termohidraulika dilakukan dengan menggunakan program Cobra IV-I dengan batasan harga Minimum Departure from Nucleate Boiling Ratio (MDNBR) yang didefinisikan sebagai rasio antara tluks kalor maksimum yang dihitung menggunakan persamaan dengan t1uks kalor setempat untuk syarat aman harus lebih besar dari 1,3. Dengan memperhitungkan ketidak tentuan dalam perhitungan tnaka harga MDNBR ditetapkan sebesar 1,6. Hasil perhitungan diperoleh muatan 4aksimum tiap target sebesar 6 gram. Perhitungan dari aspek I neutronika dilakukan dengan menggunakan program WIMS D/4 dan program BATAN2DIFF. Batasan yang digunakan dalam perhitungan neutronika adalah harga reaktivitas lebih (t.Ptarge)t maksimum lebih kecil dari 1,2 %. Dari hasil perhitungan diperoleh muatan maksimum tiap target yang dapat diiradiasi sebesar 15 gram. Dari hasil-hasil perhitungan tersebut dapat disimpulkan bahwa iradiasi FPM yang selama ini dikerjakan dengan hanya 3 gram masih dapat ditingkatkan sebesar 6 gram tiap target dan reaktor masih dalam kondisi aman.
ABSTRACT THE CALCULATION OF MO99PRODUCTION IRRADIATION OPTIMATION. The calculation of optimation loaded every target for Fission Product Molybdenum (FPM) perform in both aspect i.e. neutronically and thermohidrulically. The location simulation of every target for calculation are in the Central Irradiation Position (CIP) and Irradition Position (IP). Thermohidraulically aspect calculation performed using Cobra IV-i code, with restrict Minimum Departure from Nucleat Boiling Ratio (MDNBR) value. Definition of MDNBR is ratio of maximum heat flux calculated using equation with local heat flux for safety the values must greater than 1.3. With the calculating of uncertainty in the calculation then to determination the MDNBR value is 1.6. The resulted of calculation to got maximum loaded every target is 6 gram. Neutronically aspect calcualtion performed using WIMS D/4 code and BATAN-2 DIFF code. The restricted using in the neutronis calculation is over reactivity (t.ptarget)less than 1.2 %. The resulted of calculation to got maximum loaded every target which can irradiation is 15 gram. From the resulted of calculation we can to take conclution that FPM can be increase until 6 gram and the reactor still save.

Item Type: Article
Subjects: Taksonomi BATAN > Reaktor Nuklir > Pemanfaatan Reaktor > Iradiasi Target
Taksonomi BATAN > Reaktor Nuklir > Pemanfaatan Reaktor > Iradiasi Target
Divisions: BATAN > Pusat Reaktor Serba Guna
IPTEK > BATAN > Pusat Reaktor Serba Guna
Depositing User: Administrator Repository
Date Deposited: 21 Sep 2018 01:50
Last Modified: 02 Jun 2022 02:43
URI: https://karya.brin.go.id/id/eprint/3996

Actions (login required)

View Item
View Item