STUDI EFEK INJEKSI GAS TERHADAP KARAKTERISTIK PERPINDAHAN PANAS SUATU CAIRAN

Maman Mulyaman, MM (1996) STUDI EFEK INJEKSI GAS TERHADAP KARAKTERISTIK PERPINDAHAN PANAS SUATU CAIRAN. PROSIDING SEMINAR TEKNOLOGI DAN KESELAMATAN PLTN SERTA FASILITAS NUKLIR IV. ISSN 0854-2810

[thumbnail of 0653.pdf]
Preview
Text
0653.pdf

Download (4MB) | Preview

Abstract

Abstrak
STUDI EFEK INJEKSI GAS TERHADAP KARAKTERISTIK
PERPINDAHAN PANAS SUATU CAIRAN. Penukaran panas pada FBR tipe loop
terdiri dari sistem sodium primer, sistem sodium sekunder, dan sistem uap tersier.
Adanya sistem sodium sekunder menyebabkan bla'la untuk membangun FBRjauh
lebih mahal dari pada reaktor air rii1gan (LWRI Untuk mengatasi masalah ini,
dibuat sebuah konsep maju untuk FBR tipe loop 01mana sistem sodium sekunder
dihilangkan. Dalam konsep maju ini, sistem sotlum primer dan sistern uap air
tersier disusun dalam sebuah tangki yang berisl medium perantara yang diinjeksi
gelembung gas. Langkah awal untuk mengujl kelayakan konsep tersebut telah
dilakukan dengan mengadakan percobaan perpindahan panas pada air yang
diinjeksi oleh gas Nitrogen (Nz) sebagai medium perantara perpindahan panas.
Batang pemanas listrik dengan diameter 12 mm dan panjang aktif 220 mm sebagai
sistem sodium primer. Sistem pendingin yang berupa pipa helikal koil berdiameter
12 mm dengan ketebalan 1 mm mengelilingi batar'lgpemanas listrik sebagai sistem
tersier. Hasil percobaan menyatakar. bahwa : injeksi gelembung gas ke air dapat
menaikkan koefisien perpindahan panas, sehingga konsep ini layak diterapkan
untuk medium perantara perpindahan panas.
Abstract
STUDIES OF GAS INJECTION EFFECTS ON HEAT TRANSFER
CHARACTERISTICS OF LIQUID. Heat exchanger of loop type FBR consists of
primary sodium system, secondary sodium system. and tertiary steam system. The
existence of secondary sodium system, causes that the capital cost of FBR is very
high than that of light water reactor (LWR). To overcome this problem, an advanced
concept for loop type FBRs was proposed where the loop of the secondary sodium
system is dispensed with. In this advanced concepts, primary sodium system and
tertiary steam system arrayed in the tank with Intermediate medium which gas
bubble injectin in it. The first step experiment concerning those concepts have
been done by Nitrogen (Nz) gas injection to the water as intermediate heat transfer
medium. Electrical heater rod with 12 mm diameter and 220 mm active long as
primary sodium system. Coolant system of helical coil with 12 mm in diameter and
1 mm in thickness coiled around heater rod as tertiary water system. The
experiment results that: The bubble gas injection In the water could increase heat
transfer coefficients, so this concept is acceptable to be used at liquid metals as
intermediate medium heat transfers.

Item Type: Article
Subjects: Taksonomi BATAN > Reaktor Nuklir > Teknologi Reaktor > Kimia Reaktor
Taksonomi BATAN > Reaktor Nuklir > Teknologi Reaktor > Kimia Reaktor
Divisions: BATAN > Pusat Reaktor Serba Guna
IPTEK > BATAN > Pusat Reaktor Serba Guna
Depositing User: Administrator Repository
Date Deposited: 10 Aug 2018 02:12
Last Modified: 02 Jun 2022 02:47
URI: https://karya.brin.go.id/id/eprint/3687

Actions (login required)

View Item
View Item