TEKNIK ELIMINASI RADIASI LATAR PADA PEMBACAAN DOSIMETER PASIF UNTUK PEMANTAUAN LINGKUNGAN

Yus Rusdian Akhmad, YRA (1995) TEKNIK ELIMINASI RADIASI LATAR PADA PEMBACAAN DOSIMETER PASIF UNTUK PEMANTAUAN LINGKUNGAN. Prosiding Seminarke-3 Teknologi dan Keselamatan PLTN serta Fasilitas NUklir. ISSN 0854-2910

[thumbnail of 0613.pdf]
Preview
Text
0613.pdf

Download (3MB) | Preview

Abstract

ABSTRAK.
TEKNIK ELiMINASI RADIASI LATAR PADA PEMBACAAN DOSIMETER PASIF UNTUK
PEMANTAUAN LlNGKUNGAN. Oibahas suatu teknik mengeliminasi sumbangan latar untuk pengukuran
peningkatan dosis radiasi yang disebabkan oleh beluk radioaktif atau radiasi terhambur ke permukaan
tanah di sekitar fasilitas nukJir dengan menggunakan dosimeter pas if. Untuk mengeJiminasi Jatar, teknik ini
memanfaatkan perisai Pb dan lokasi kontrol. Oengan menggunakan dua jenis dosimeter pasif yaitu
dosimeter gelas (PLO SC-1) dan dosimeter termoluminesensi (TLO CaSO4:Tm), telah dilaksanakan tiga
kali pengukuran paparan radiasi secara bulanan di sekitar tempat penyimpanan Jimbah radioaktif Japan
Atomic Energy Research Institute (JAERI) di tapak Oarai dan Tokaimura untuk mengevaluasi kinerjanya.
Evaluasi dilakukan dengan cara membandingkan hasilnya terhadap niJai acuan. NiJai acuan diperoleh dari
pengukuran menggunakan detektor berbentuk bola Nal(TI) berdiameter 7.5 cm dan fungsi G(E) yang
mengkonversi responnya menjadi besaran paparan. Oengan mengoreksi hasil dari TLO sehubungan
dengan efek kebergantungan energi, hampir seluruh hasil dari tiga kali pengukurannya sesuai dengan nilai
acuan. Oibandingkan dengan TLO, hasiJ yang diperoleh berdasarkan pembacaanPLOlebih mendekati nilai
acuan. Teknik ini menjanjikan prosedur sederhana tetapi akurat untuk mengeliminasi J~tar dalam estimasi
peningkatan dosis.
ABSTRACT.
A METHOD FOR SEPARATING BACKGROUND FROM PASSIVE DOSIMETERS READING IN
ENVIRONMENTAL MONITORING. A simple method using passive dosemeters for estimating elevated
dose in the vicinity of nuclear facility due to downward radiation arising from the plume discharge and direct
or scatteredc radiations was presented.. In, eliminating the background this method rely on lead shields and a
control location. By using two different types of passive dosemeter, photoluminescence dosemeter (PLD
SC-1) and thermoluminescence dosemeter (TLO CaSO4:Tm), three runs of monthly measurement have
been performed to evaluate the applicability in isolating the elevated dose at locations close to the
radioactive waste storage in the Oarai site and Tokaimura site of the Japan Atomic Energy Research
Institute (JAERI). The results obtained were intercompared with the reference values those measured with a
3" ~spherical Nal(TI) detector applying a function G(E). By correcting the results of the TLD by a correction
factor associated with the energy dependence effect, almost all of the results of the three runs were in
agreement within the limits of uncertainty. Compared with the reference values, the results based on the
PLO's reading are closer than those the TLO one. This method provides a simple procedure to eliminate the
background dose in estimating the elevated' dose accurately.

Item Type: Article
Subjects: Taksonomi BATAN > Keselamatan dan Keamanan Nuklir > Keselamatan Lingkungan > Keselamatan Radiasi Lingkungan
Taksonomi BATAN > Keselamatan dan Keamanan Nuklir > Keselamatan Lingkungan > Keselamatan Radiasi Lingkungan
Divisions: BATAN > Pusat Reaktor Serba Guna
IPTEK > BATAN > Pusat Reaktor Serba Guna
Depositing User: Administrator Repository
Date Deposited: 09 Aug 2018 04:19
Last Modified: 02 Jun 2022 02:47
URI: https://karya.brin.go.id/id/eprint/3678

Actions (login required)

View Item
View Item