ANALISIS PARAMETER KINETIK DAN TRANSIEN TERAS KOMPAK REAKTOR RSG-GAS

Iman Kuntoro, IK and Surian Pinem, SP and Tagor Malem Sembiring, TMS (2010) ANALISIS PARAMETER KINETIK DAN TRANSIEN TERAS KOMPAK REAKTOR RSG-GAS. ANALISIS PARAMETER KINETIK DAN TRANSIEN TERAS KOMPAK REAKTOR RSG-GAS, 12 (3). pp. 146-152. ISSN 2527

Full text not available from this repository.

Abstract

Dalam rangka meningkatkan efisiensi penggunaan bahan bakar reaktor RSG-GAS telah dilakukan studi penentuan teras kompak. Hasil perhitungan parameter neutronik menunjukkan bahwa teras kompak dengan menutup empat fasilitas iradiasi (IP) dengan elemen bakar dapat meningkatkan siklus operasi 23,6 %. Selanjutnya perlu dilakukan penentuan parameter kinetik dan analisis transien teras kompak untuk mengetahui keselamatan operasi reaktor. Perhitungan dilakukan dengan menggunakan program WIMS/D4 untuk generasi konstanta difusi sel elemen bakar dan MTRDYN untuk menentukan parameter kinetik dan analisis transien. Hasil perhitungan menunjukkan bahwa harga fraksi neutron kasip total teras kompak naik 2 % dan umur neutron serempak turun 8,3 % dibandingkan dengan teras setimbang. Temperatur maksimum bahan bakar saat transien pada daya awal 1 W adalah 71,64 0C dan pada daya 1 MW adalah 129,60 0C. Hasil ini menunjukkan bahwa teras kompak RSG-GAS aman digunakan sebagai teras alternatif.

Kata kunci: parameter kinetik, transien, reaktor

For increasing the efficiency of fuel element of the RSG-GAS reactor, some alternative configuration has been searched to obtain a compact core configuration. Calculation result of the neutronics parameters that the compact core with insertion fuel element to all irradiation facility (IP) can increase operation cycle length to about 23.6 %. Then, it is necessary to calculate the kinetic parameters and transient analysis of the compact core to verify the reactor operation safety. Calculations were performed by means of WIMS/D4 and MTRDYN code for generation of cell diffusion constants and for kinetic parameters and transient analysis respectively. The result showed that the total delayed neutron fraction of compact core increases by 2 % and the prompt neutron lifetime decreases 8.3 % compared to the equilibrium core. Maximum temperature of the fuel element at transient at initial power of 1 W is 71.64 0C and at the power 1 MW is 126.60 0C. The result showed that the compact core of RSG-GAS reactor can be used as alternative core safely.

Keywords: kinetic parameter, transient, reactor.

Item Type: Article
Subjects: Taksonomi BATAN > Keselamatan dan Keamanan Nuklir
Taksonomi BATAN > Keselamatan dan Keamanan Nuklir
Divisions: BATAN > Pusat Teknologi dan Keselamatan Reaktor Nuklir
IPTEK > BATAN > Pusat Teknologi dan Keselamatan Reaktor Nuklir
Depositing User: Administrator Repository
Date Deposited: 28 Jun 2018 01:35
Last Modified: 02 Jun 2022 02:28
URI: https://karya.brin.go.id/id/eprint/3139

Actions (login required)

View Item
View Item