M. Hadi Kusuma, MHK and Mulya Juarsa, MJ and Anhar Riza Antariksawan, ARA and Nandy Putra, NP (2012) ANALISA PENGARUH SUHU AWAL PELAT PANAS PADA PROSES QUENCHING CELAH SEMPIT REKTANGULAR. ANALISA PENGARUH SUHU AWAL PELAT PANAS PADA PROSES QUENCHING CELAH SEMPIT REKTANGULAR, 14 (2). pp. 108-120. ISSN 2527-9963
Full text not available from this repository.Abstract
Pemahaman terhadap manajemen termal apabila terjadi suatu kecelakaan parah reaktor nuklir seperti melelehnya bahan bakar dan teras reaktor, menjadi prioritas utama untuk menjaga integritas bejana tekan reaktor. Dengan demikian hasil lelehan bahan bakar dan teras reaktor (debris) tidak keluar dari bejana tekan reaktor dan mengakibatkan dampak lain yang lebih besar ke lingkungan. Salah satu cara yang dilakukan untuk menjaga integritas bejana tekan reaktor adalah dengan melakukan pendinginan terhadap panas berlebih yang dihasilkan akibat dari kecelakaan tersebut. Untuk mempelajari dan mendapatkan pemahaman mengenai hal tersebut, maka dilakukan penelitian mengenai pengaruh suhu awal pelat panas dalam proses quenching (pendinginan secara tiba-tiba) celah sempit rektangular. Penelitian difokuskan pada penentuan suhu rewetting dari pendinginan pelat panas dengan suhu awal pelat 220 0C, 400 0C, dan 600 0C dengan laju aliran air pendingin 0,2 liter/detik. Eksperimen dilakukan dengan menginjeksikan air pada laju aliran 0,2 liter/detik pada suhu air pendingin 85 0C ke dalam celah sempit rektangular. Data hasil pengukuran digunakan untuk mengetahui suhu rewetting yang terjadi pada pendinginan pelat panas tersebut. Tujuannya adalah untuk memahami pengaruh suhu awal pelat panas terhadap rewetting pada proses quenching di celah sempit rektangular. Hasil yang diperoleh menunjukkan bahwa titik rewetting pada pendinginan pelat panas 220 0C, 400 0C, dan 600 0C terjadi pada suhu rewetting yang berbeda-beda. Pada suhu awal pelat panas 220 0C, suhu rewetting terjadi pada 220 0C yaitu langsung ketika air dilewatkan melalui celah sempit rektangular. Pada suhu awal pelat panas 400 0C, suhu rewetting terjadi pada 379,51 0C. Dan pada suhu awal pelat panas 600 0C, suhu rewetting terjadi pada 426,63 0C. Perbedaan suhu awal pelat panas yang sangat signifikan menyebabkan terjadinya perubahan sifat fisik benda uji, berbedanya rejim pendidihan yang dialami oleh fluida yang melewati celah sempit, perubahan nilai kalor spesifik bahan, perubahan nilai konduktifitas termal, dan perbedaan suhu wall superheated-nya. Perubahan-perubahan yang terjadi tersebut menyebabkan peningkatan suhu rewetting seiring dengan kenaikan suhu awal pelat panas.
Kata kunci: rewetting, quenching, celah sempit, keselamatan nuklir
The understanding about thermal management in the event of a severe accident such as the melting nuclear reactor fuel and reactor core, became a priority to maintain the integrity of reactor pressure vessel. Thus the debris will not out from the reactor pressure vessel and resulting impact of more substantial to the environment. One way to maintain the integrity of the reactor pressure vessel was cooling of the excess heat generated due to the accident. Toget understanding of this aspect, the research focused on the effect of the initial temperature of the hot plate in the rectangular narrow gap quenching process. The initial temperature effect on quenching process is related to cooling process (thermal management) when the occurrence of a nuclear accident due to loss of coolant accident or severe accident. In order to address the problem, it is crucial to conduct research to get a better understanding of thermal management regarding to nuclear cooling accident. The research focused on determining the rewetting temperature of hot plate cooling on 220 0C, 400 0C, and 600 0C with 0.2 liters/sec cooling water flowrate. Experiments were carried out by injecting 85 0C cooling water temperature into the narrow gap at flowrates of 0.2 liters/sec. Data of transient temperature measurements were recorded using a data acquisition system in order to know the rewetting temperature during the quenching process. This study aims to understand the effect of hot plate intial temperature on rewetting during rectangular narrow gap quenching process. The results obtained show that the rewetting point on cooling the hot plate 220 0C, 400 0C and 600 0C occurs at varying rewetting temperatures. At 220 0C hot plate initial temperature, the rewetting temperature occurs on 220 0C. At 400 0C hot plate initial temperature, the rewetting temperature occurs on 379.51 0C. At 600 0C hot plate initial temperature, the rewetting temperature occurs on 426.63 0C. Significant differences of hot plate initial temperature leads to changes in physical properties of material, different boiling regimes occurs when fluid passing through a narrow gap, changes on specific heat of material, changes on thermal conductivity of material, and the differences of wall superheated temperature. Rewetting temperature will increase due to increasing on hot plate initial temperature.
Keywords: rewetting, quenching, narrow gap, nuclear safety
Item Type: | Article |
---|---|
Subjects: | Taksonomi BATAN > Keselamatan dan Keamanan Nuklir Taksonomi BATAN > Keselamatan dan Keamanan Nuklir |
Divisions: | BATAN > Pusat Teknologi dan Keselamatan Reaktor Nuklir IPTEK > BATAN > Pusat Teknologi dan Keselamatan Reaktor Nuklir |
Depositing User: | Administrator Repository |
Date Deposited: | 28 Jun 2018 01:34 |
Last Modified: | 31 May 2022 09:21 |
URI: | https://karya.brin.go.id/id/eprint/3087 |