DIGITALISASI SISTEM PENGUKURAN FLUKS NEUTRON REAKTOR RSGGAS BERBASIS LABVIEW

Agus Nur Rachman, ANR and Muhammad Subekti, MS and Kussigit Santosa, KS and Ranji Gusman, RG (2016) DIGITALISASI SISTEM PENGUKURAN FLUKS NEUTRON REAKTOR RSGGAS BERBASIS LABVIEW. In: Prosiding Seminar Nasional Teknologi Energi Nuklir 2016, 4-5 Agustus 2016, BATAM.

[thumbnail of PROSIDING_SENTEN_2016.pdf]
Preview
Text
PROSIDING_SENTEN_2016.pdf

Download (145MB) | Preview

Abstract

ABSTRAK
DIGITALISASI SISTEM PENGUKURAN FLUKS NEUTRON REAKTOR RSG-GAS BERBASIS
LABVIEW. Salah satu parameter penting yang selalu diamati saat pengoperasian reaktor RSGGAS
adalah nilai fluks neutron. Saat ini pembacaan nilai fluks neutron masih dilakukan secara
manual dengan membaca meter analog. Pembacaan meter analog memiliki kesulitan tersendiri
antara lain memungkinkan terjadinya kesalahan paralak, kesulitan menentukan nilai saat jarum
menunjuk diantara dua garis nilai. Digitalisasi sistem pengukuran fluks neutron pada reaktor RSGGAS
dilakukan untuk memberi kemudahan pada operator dalam pembacaan nilai pengukuran.
Penelitian ini dilakukan dengan menggunakan metode eksperimen yang dibagi menjadi tiga tahap,
yaitu ; pengambilan data, konversi dan pembuatan graphical user interface (GUI). Pengambilan
data dilakukan dengan mengukur keluaran dari sistem instrumentasi reaktor yang berupa arus
searah dengan rentang 0-20 mA yang berbanding lurus dengan perubahan nilai fluks neutron.
Data hasil pengukuran sistem instrumentasi reaktor digunakan sebagai dasar untuk melakukan
konversi nilai arus terukur dengan tampilan fluks neutron pada meter analog. Tahap selanjutnya
adalah memasukkan hasil perhitungan konversi kedalam perangkat lunak LabVIEW, yang juga
digunakan untuk membuat graphical user interface (GUI) tampilan digital sistem pengukuran fluks
neutron. Tampilan dibuat menyesuaikan dengan kondisi riil dengan menampilkan nilai digital,
meter, dan grafik pengukuran fluks neutron. Hasil pengujian menunjukkan bahwa LabVIEW dapat
menampilkan nilai digital hasil pengukuran dan grafik fluks neutron pada layar komputer dan dapat
mengakuisisi data selama operasi reaktor berlangsung. Hasil uji fungsi menunjukkan pada kanal
JKT01 persente kesalahan terbesar adalah 7% pada arus 20 mA. Pada kanal JKT02 persentase
kesalahan terbesar adalah 22% pada arus 20mA. Sedangkan pada kanal JKT03 persentase
kesalahan terbesarnya hanya 0,04%.
Kata kunci: Digitalisasi, Sistem Pengukuran, Fluks Neutron, LabVIEW.
ABSTRACT
DIGITALIZATION NEUTRON FLUKS MEASUREMENT SYSTEM IN RSG-GAS REACTORS
BASED ON LABVIEW. One of the important parameter monitored during operation reactor RSGGAS
is the value of the neutron flux. Currently reading neutron flux value is still done manually by
reading the analog meter. There is one dificulty in reading analog meter which allow parallax Error
in determining the current value of the needle points between the two lines of values. Digitalization
neutron flux measurement system in reactor RSG-GAS is done to assist the operator in reading
measurement values. This research was conducted using the experimental method that divided
into three stages there are : data collection, conversion and manufacture of graphical user
interface (GUI). Data collection was performed by measuring the output of the reactor
instrumentation system in the form of direct current with a range of 0-20 mA that is directly
proportional to the change in the value of the neutron flux. Data from the measurements of reactor
instrumentation system were used as a basis for conversion of measured current value with the
display of the neutron flux in the analog meter. The next stage is inserting conversion calculation
results into LabVIEW software, which is also used to create a graphical user interface (GUI) display
for digital neutron flux measurement system. . The appearance on GUI was made with adapted to
the real conditions to display a digital value, meter, and graphs of neutron flux measurement. The
test results indicate that LabVIEW can display digital value measurements and the neutron flux
graphs on the computer screen. Function test results showed the biggest error percentage on
JKT01 was 7% at 20 mA. On the channel JKT02 The error percentage is 22% at 20mA. While on
the channel JKT03 The error percentage is only 0,04%.
Keyword: Digitalization, Data acquisition, neutron flux, RSG-GAS, LabVIEW.

Item Type: Conference or Workshop Item (Paper)
Subjects: Taksonomi BATAN > Keselamatan dan Keamanan Nuklir
Taksonomi BATAN > Keselamatan dan Keamanan Nuklir
Divisions: BATAN > Pusat Teknologi dan Keselamatan Reaktor Nuklir
IPTEK > BATAN > Pusat Teknologi dan Keselamatan Reaktor Nuklir
Depositing User: Administrator Repository
Date Deposited: 21 May 2018 06:17
Last Modified: 31 May 2022 04:42
URI: https://karya.brin.go.id/id/eprint/2173

Actions (login required)

View Item