Giarno, GN and G.B. Heru K, GBHK and Joko Prasetio Witoko, JPW and Mulya Juarsa, MJ (2016) KARAKTERISASI PRE-COOLER SEBAGAI SISTEM HEAT SINK PADA UNTAI FASSIP-01. In: Prosiding Seminar Nasional Teknologi Energi Nuklir 2016, 4-5 Agustus 2016, BATAM.
PROSIDING_SENTEN_2016.pdf
Download (145MB) | Preview
Abstract
ABSTRAK
KARAKTERISASI PRE-COOLER SEBAGAI SISTEM HEAT SINK PADA UNTAI FASSIP-
01. Konsep keselamatan pasif digunakan untuk meningkatkan keamanan dan keselamatan
PLTN. Sistem pasif merupakan sistem pembuang kalor dengan mengasumsikan tidak
tersedianya pompa serta gagal beroperasinya generator diesel. Untuk mendalami teknologi
sistem pasif dibuat fasilitas eksperimen baru di laboratorium Termohidrolika, BPFKRPTKRN-BATAN,
yaitu untai Fasilitas Simulasi Sistem Pasif (FASSIP-01). Untai FASSIP-01
terdiri dari Rectangular loop (sistem primer) dan sistem pendingin (sistem sekunder) serta
sistem Heat Sink (sistem tersier). Sistem Heat Sink berfungsi untuk mengambil kalor dari
tangki Cooler lalu membuang ke lingkungan. Sistem Heat Sink terdiri dari tangki pendingin
mula (Pre-cooler) dan mesin refrigerasi (Refrigerator). Tujuan penelitian adalah untuk
mengetahui karakteristik Pre-cooler sebagai sistem Heat Sink untai FASSIP-01 dalam
kemampuannya menyerap kalor dari Rectangular loop dan membuang ke lingkungan.
Karakteristik Pre-cooler diperoleh dengan cara fabrikasi Pre-heater dimodifikasi menjadi Precooler,
melakukan eksperimen dan membuat grafik. Eksperimen dan pembuatan grafik
memperoleh karakterisasi Pre-cooler dan terlihat nilai laju aliran massa air semakin naik,
maka jumlah kalor yang diserap semakin naik, kemudian berhenti naik pada laju aliran
massa air sebesar 0,57 kg/s dengan jumah kalor yang diserap sebesar 11,99 W, hal ini
menunjukkan kemampuan Pre-cooler sebagai sistem Heat Sink untai FASSIP-01 bekerja
optimal pada daerah kerja mulai laju aliran massa air 0,18 – 0,57 kg/s.
Kata kunci: Pre-cooler, Heat Sink, untai FASSIP-01, sistem pasif.
ABSTRACT
CHARACTERIZATION OF THE PRE-COOLER AS THE HEAT SINK SYSTEM OF THE
LOOP FASSIP-01. The concept of passive safety is used to increase the safety of nuclear
power plants. Passive system is a system, which can work without pump and generator
diesel. In order to understand the concept of passive system, a passive system facility
FASSIP-01 has been built in the thermal hydraulic laboratory, BPFKR-PTKRN-BATAN. Loop
FASSIP-01 consists of a rectangular loop (the primary system), a cooling system (the
secondary system) and a Heat Sink system (the tertier system). The function of the Heat
sink system is to remove heat from the tank cooler into the environment. The Heat Sink
system consists of a initiated cooling tank (Pre-cooler) and refrigeration machine
(Refrigerator). The purpose of this research is to know characteric of the Pre-cooler as the
Heat Sink system of the loop FASSIP-01 to absorb heat engine of rectangular loops and
throw it into the environment. Characterization of the Pre-cooler is done by modifying Preheater
to become Pre-cooler, performing an experiment and drawing a chart. Experiment
and the manufacture of the graph obtained characterization of the Pre-cooler is seen to rise
and the value of the mass flowrate of water, rising the amount of heat engine which it is
absorbed and then stopped rising at the mass flowrate of water 0,57 kg/s and the amount of
heat engine which it is absorbed 11,99 W, it is demonstrating ability the Pre-cooler as the
Heat Sink system for the loop FASSIP-01 to optimal work at the mass flowrate of water
0,18 - 0,57 kg/s.
Keywords: Pre-cooler, Heat Sink, the loop FASSIP-01, passive system.
Item Type: | Conference or Workshop Item (Paper) |
---|---|
Subjects: | Taksonomi BATAN > Keselamatan dan Keamanan Nuklir Taksonomi BATAN > Keselamatan dan Keamanan Nuklir |
Divisions: | BATAN > Pusat Teknologi dan Keselamatan Reaktor Nuklir IPTEK > BATAN > Pusat Teknologi dan Keselamatan Reaktor Nuklir |
Depositing User: | Administrator Repository |
Date Deposited: | 21 May 2018 06:16 |
Last Modified: | 31 May 2022 04:44 |
URI: | https://karya.brin.go.id/id/eprint/2158 |