Karakteristik dan efektifitas menara pendingin reaktor triga 2000

Reinaldy Nazar and Dudung A.R and Masri Z (2004) Karakteristik dan efektifitas menara pendingin reaktor triga 2000. PROSIDING PERTEMUAN DAN PRESENTASI ILMIAH PENELITIAN DASAR ILMU PENGETAHUAN DAN TEKNOLOGI NUKLIR: 10. pp. 1-8. ISSN 0216-3128

[thumbnail of 10 Proceeding_Reinaldi_BATAN_2004.pdf]
Preview
Text
10 Proceeding_Reinaldi_BATAN_2004.pdf - Published Version

Download (1MB) | Preview

Abstract

Menara pendingin sebagai bagian dari sistem pendingin sekunder reaktor TRIGA 2000 berfungsi untuk menurunkan temperatur air pendingin sekunder yang berasal dari alat penukar kalor, selanjutnya kalor yang terjadi dibuang ke lingkungan. Untuk mengetahui kemempuan menara pendingin di dalam menurunkan temperatur air pendingin sekunder perlu dilakukan analisis karakteristiknya secara berkala. Efektivitas menara pendingin dihitung berdasarkan laju perpindahan kalor nyata dibagi dengan laju perpindahan kalor maksimum yang mungkin dicapai. Hasil penelitian menunjukkan bahwa efektifitas menara pendingin utara dan menara pendingin selatan pada daya 250kW berturut-turut = 8% dan 7% pada daya 500kW=7% dan 11% pada daya 750kW=24% dan 24% pada daya 1750kW=22% dan 26% serta pada daya 2000kW=19% dan 23%

THE CHARACTERISTIC AND EFFECTIVITY OF THE TRIGA 2000 REACTOR COOLING TOWER. Coolig tower as part of secondary cooling system of the TRIGA 2000 reactor, has a function to reduce water temperature come from heat exchanger, furthermore the heat energy would be exchaused to environment. To know the capability of the cooling tower in reducing temperature of secondary water, it is required an analyses the characteristic of the system periodically. On this analyse, the effectivity of cooling tower was calculated based on the real heat transfer and south cooling lower at power 250 kW respectively - 8% and 7 %, at power 500 kW = 7 % and 11 %, at power 750 kW = 14 % and 20 % at power 1000 kW = 20 % and 17 %, at power 1250 kW = 21 % and 17 %, at power 1500 kW = 24% and 24%, at power 1750 kW = 22 % and 26 %, at power 2000 kW = 19 % and 23 %.

Item Type: Article
Uncontrolled Keywords: karakteristik, efektivitas, menara pendingin, characteristic, effectivity, cooling tower, reactors (nuclears), cooling towers
Subjects: Taksonomi BATAN > Reaktor Nuklir > Pemanfaatan Reaktor
Taksonomi BATAN > Reaktor Nuklir > Pemanfaatan Reaktor
Taksonomi BATAN > Reaktor Nuklir > Pemanfaatan Reaktor > Eksperimen Reaktor
Taksonomi BATAN > Reaktor Nuklir > Pemanfaatan Reaktor > Eksperimen Reaktor
Taksonomi BATAN
Divisions: BATAN > Pusat Kajian Sistem Energi Nuklir
IPTEK > BATAN > Pusat Kajian Sistem Energi Nuklir
Depositing User: Sdr Atam Ependi
Date Deposited: 02 Oct 2023 03:24
Last Modified: 02 Oct 2023 03:24
URI: https://karya.brin.go.id/id/eprint/20105

Actions (login required)

View Item
View Item