Dedy Haryanto, DH (2016) ANALISIS KEKUATAN MEKANIK STRUKTUR UNTAI UJI TERMOHIDROLIKA REAKTOR MENGGUNAKAN PERANGKAT LUNAK UJI STRUKTUR. In: Prosiding Seminar Nasional Teknologi Energi Nuklir 2016, 4-5 Agustus 2016, BATAM.
PROSIDING_SENTEN_2016.pdf
Download (145MB) | Preview
PROSIDING_SENTEN_2016.pdf
Download (145MB) | Preview
Abstract
ABSTRAK
ANALISIS KEKUATAN MEKANIK STRUKTUR UNTAI UJI TERMOHIDROLIKA
REAKTOR MENGGUNAKAN PERANGKAT LUNAK UJI STRUKTUR.
Station Black Out
(SBO) terjadi karena tidak adanya catu daya listrik bagi sistem aktif untuk mendinginkan
teras reaktor. Akibatnya panas sisa terkumpul di
containment
dan terjadi kenaikkan tekanan
serta temperatur yang tinggi di
Reactor Pressure Vessel
(RPV) berakibat RPV meledak.
Berdasakan kejadian tersebut diperlukan sistem keselamatan pasif untuk membuang sisa
panas hasil peluruhan yang dihasilkan ketika SBO terjadi. Maka perlu dilakukan penelitian
tentang sistem pasif sebagai pendukung sistem aktif untuk menjamin keselamatan reaktor
nuklir. Sistem pasif tersebut adalah Fasilitas Eksperimen-
Passive Residual Heat Removal
System
(FASE-PRHRS) dengan menggunakan struktur UUTR. Penelitian dilakukan secara
bertahap, pada tahap ini dilakukan analisis kekuatan mekanik pada struktur Untai Uji
Termohidrolika Reaktor (UUTR) untuk mengetahui kekuatan struktur dengan beban UUTR.
Langkah-langkah yang dilakukan meliputi pengambilan data ukuran dan material struktur,
membuat gambar teknik dan model 3-dimensi struktur, mengumpulkan data-data tentang
berat komponen-komponen UUTR dan menentukan titik berat komponen sebagai beban
pada struktur serta melakukan pengujian kekuatan mekanik secara simulasi pada struktur
pada kondisi tanpa beban dan dengan beban UUTR. Hasil pengujian secara simulasi
mendapatkan tegangan mekanik maksimum yang terjadi pada struktur UUTR dengan
adanya beban berupa komponen UUTR adalah sebesar 3,91 x 10
6
N/m
2
. Jika dibandingkan
dengan
yield strength
material Carbon Steel ASTM A36 2,5x10
8
N/m
2
besaran tegangan
mekanik yang terjadi jauh lebih kecil daripada
yield strength
material yang digunakan.
Translation displacement
terbesar yaitu 0,103 mm sangat kecil dan tidak mengakibatkan
terjadinya perubahan bentuk pada struktur UUTR. Dengan demikian struktur UUTR sanggup
untuk menopang komponen UUTR.
Kata kunci
: kekuatan mekanik, struktur, termohidrolika, untai pasif
ABSTRACT
ANALYSIS MECHANICAL STRENGTH AND DESIGN PHASE-PHRASE (FACILITY
EXPERIMENTS-PASSIVE RESIDUAL HEAT REMOVAL SYSTEM) USING SOFTWARE
OF TEST OF STRUCTURE.
Station Blackout (SBO) occurs in the absence of electrical
power supply for active systems to cool the reactor core. As a result, the residual heat
accumulated in the containment and an increase in pressure and high temperature in the
Reactor Pressure Vessel (RPV) resulted in the RPV explode. Based on these events
required passive safety systems to remove excess heat generated when the decay product
of SBO occurred. It is necessary to research on passive systems to support an active system
to ensure the safety of nuclear reactors. The passive systems is Experimental Facility-
Passive Residual Heat Removal System (PHASE-PRHRS) use UUTR structure. The study
carried out in stages, this step is analyzed is the mechanical strength of strand structure
Thermohidraulica Test Reactor (UUTR) to determine the strength of the structure with a load
UUTR. The steps taken include retrieval of data size and material structure, create
engineering drawings and models of 3-dimensional structures, collecting data about the
weight of the components UUTR and determine the weight of the components as the load on
the structure as well as testing the mechanical strength is simulated on structure at no load
and load UUTR. The test results in simulation conducted obtain mechanical stresses
occurring in the structure UUTR with the load of components UUTR is equal to 3.91 x 10
6
N /
m
2
. When compared with the yield strength of the material Carbon Steel ASTM A36 2,5x10
8
N / m
2
amount of mechanical stress that occurs is much smaller than the yield strength of the
material used. Translational greatest displacement is 0,103 mm is very small and does not
result in a change in the structure form UUTR. Thus UUTR structure able to sustain of and
components UUTR.
Keywords
: mechanical strength, structure, thermohidraulica, passive loop
Item Type: | Conference or Workshop Item (Paper) |
---|---|
Subjects: | Taksonomi BATAN > Keselamatan dan Keamanan Nuklir Taksonomi BATAN > Keselamatan dan Keamanan Nuklir |
Divisions: | BATAN > Pusat Teknologi dan Keselamatan Reaktor Nuklir IPTEK > BATAN > Pusat Teknologi dan Keselamatan Reaktor Nuklir |
Depositing User: | Administrator Repository |
Date Deposited: | 15 May 2018 01:32 |
Last Modified: | 31 May 2022 04:43 |
URI: | https://karya.brin.go.id/id/eprint/1565 |