ABSTRAK
KARAKTERISASI ARUS TEMBUS KABEL PENGHANTAR PEMANAS
PADA UNTAI
FASSIP-01.
Untai FASSIP-01 merupakan sebuah peralatan eksperimen dimana aliran
fluidanya dapat bergerak secara alamiah karena adanya beda temperatur. Untai uji FASSIP-
01 menggunakan empat buah pemanas, daya setiap pemanasnya sebesar 5 kW. Kabel
penghantar untuk daya sebesar ini harus memenuhi persyaratan arus tembus maksimal dan
tahanan isolasi yang telah ditentukan. Walaupun bahan-bahan isolasi yang digunakan cukup
baik dan mempunyai tahanan isolasi yang tinggi, tetapi masih ada tempat-tempat yang
lemah pada lapisan isolasinya.Tujuan penelitian adalah untuk mendapatkan karakteristik
arus tembus kabel penghantar yang digunakan pada untai FASSIP-01. Metode yang
digunakan adalah dengan cara memberikan tegangan pada kabel penghantar mulai dari 0,5
kV s/d 5 kV, lalu dilakukan pencatatan hasil pengukuran arus tembus. Variasi tegangan 0,5
s/d 5 kV dimaksudkan untuk mendapatkan data yang lebih akurat sedangkan tegangan yang
cukup tinggi digunakan untuk menentukan kekuatan bahan isolasi kabel penghantar. Hasil
pengukuran arus tembus sebesar 0,193 mA s/d 2,270 mA, linear terhadap tegangan
inputnya. Berdasarkan perhitungan tahanan isolasi diperoleh sebesar 2.500 kOhm,
lebih
tinggi dari tahanan isolasi minimal yang dipersyaratkan sebesar 242 kOhm.
Kata kunci: pemanas, kabel penghantar, arus tembus, untai FASSIP-01
ABSTRACT
CHARACTERIZATION FLOW THROUGH HEATER CABLE CONDUCTOR ON THE LOOP
FASSIP-01.
Loop FASSIP-01 was an experimental apparatus in which the fluid flow can
move naturally because of the temperature difference. Loop FASSIP-01 using four heaters,
the heating power of 5 kW each. Conductor cables for the power of this magnitude should
meet the requirements of the current maximum translucency and insulation resistance is
predetermined. Although the insulating materials used is quite good and has a high
insulation resistance, but there are still places that are weak in research insulation material.
The research objective is to get a current characteristic translucent conductive wires used in
the loop FASSIP-01. The method used is by applying a voltage to the conductive wires
ranging from 0.5 kV until 5 kV, and also recorded the current measurement results
translucent. Voltage variation of 0.5 until 5 kV intended to obtain more accurate data, while a
high enough voltage is used to determine the strength of the cable insulation material
conductive. The measurement results translucent flow of 0.193 mA until 2.270 mA, linear
with respect to the input voltage. Based on calculations obtained insulation resistance of
2,500 kOhm, higher than the required minimum insulation resistance of 242 kOhm.
Key words: heating, cable conductor, flow-through, loop FASSIP-01

Item Type: Conference or Workshop Item (Paper)
Subjects: Taksonomi BATAN > Keselamatan dan Keamanan Nuklir
Taksonomi BATAN > Keselamatan dan Keamanan Nuklir
Divisions: BATAN > Pusat Teknologi dan Keselamatan Reaktor Nuklir
IPTEK > BATAN > Pusat Teknologi dan Keselamatan Reaktor Nuklir
Depositing User: Administrator Repository
Date Deposited: 14 May 2018 08:50
Last Modified: 31 May 2022 04:43
URI: https://karya.brin.go.id/id/eprint/1560

Actions (login required)

View Item
View Item