PERHITUNGAN KEKUATAN LASAN PADA PENYANGGA TANGKI PENDINGIN DAN TANGKI PEMANAS DI UNTAI FASSIP-01

Joko Prasetio W, JPW and Edi Marzuki, EM (2016) PERHITUNGAN KEKUATAN LASAN PADA PENYANGGA TANGKI PENDINGIN DAN TANGKI PEMANAS DI UNTAI FASSIP-01. In: Seminar Nasional Teknologi Energi Nuklir 2016, 4 - 5 Agustus 2016, Batam.

[thumbnail of PROSIDING_SENTEN_2016.pdf]
Preview
Text
PROSIDING_SENTEN_2016.pdf

Download (145MB) | Preview

Abstract

ABSTRAK
PERHITUNGAN KEKUATAN LASAN PADA PENYANGGA TANGKI PEMANAS DAN
TANGKI PENDINGIN DI UNTAI FASSIP-01.
perhitungan kekuatan las didasari pada
pertimbangan faktor keamanan dari konstruksi rangka utama dan komponen tambahan
seperti tangkai pemegang untuk pendinginan dan pemanasan tangki. Kekuatan sambungan
las dipengaruhi oleh; jenis bahan logam induk, jenis bahan pengisi, bentuk sambungan las
yang digunakan, tinggi dan panjang sambungan las, arah dan beban seperti yang terjadi.
Komponen tangkai pemegang menggunakan bahan UNP50 profil dengan ukuran 50 × 30 × 5
mm dan panjang 400 mm yang dilas ke rangka utama menggunakan jenis elektroda E7013
dengan diameter 2,4 mm. Hasil perhitungan menunjukkan bahwa jenis sambungan temu
(butt-joint) mampu mendukung beban arah vertikal sebesar 652 kN, beban arah horizontal
sebesar 785 kN, dan beban eksentrik sebesar 803 kN. Sedangkan penggunaan sambungan
tumpang (lap-joint) mendapatkan peningkatan sebesar 40% untuk beban arah vertikal, 37%
untuk beban arah horizontal, dan 47% untuk beban eksentrik, sebagai hasil perhitungan
dengan memasukkan nilai faktor keamanan (safety factor).
Kata kunci: kekuatan las, tangkai pemegang, tangki pemanas, tangki pendingin, FASSIP-01
ABSTRACT
CALCULATION OF WELD STRENGTH BUFFER TANK TANK HEATING AND COOLING
IN strand FASSIP-01
. weld strength calculation is based on a consideration of the safety of
the construction of the main frame and additional components such as stems holder for
cooling and heating tank. Influenced by the strength of welded joints; type of parent metal,
type of filler, the shape of the weld joint is used, the height and length of the weld joint,
directions and expenses as it happens. Components stalk holder uses the profile UNP50
material with a size of 50 × 30 × 5 mm and a length of 400 mm are welded to the main frame
using E7013 electrode type with a diameter of 2.4 mm. The calculations show that the
connection type Intersection (butt-joint) capable of supporting a load of 652 kN the vertical
direction, horizontal direction load of 785 kN, and the eccentric load of 803 kN. While the use
of overlapping connection (lap-joint) get an increase of 40% for loads vertical direction, 37%
for load horizontal direction, and 47% for the eccentric load, to the calculation results with or
without the value of the safety factor (safety factor).
Keywords: weld strength, haft-holder, heating tanks, cooling tanks, FASSIP-01

Item Type: Conference or Workshop Item (Paper)
Subjects: Taksonomi BATAN > Keselamatan dan Keamanan Nuklir
Taksonomi BATAN > Keselamatan dan Keamanan Nuklir
Divisions: BATAN > Pusat Teknologi dan Keselamatan Reaktor Nuklir
IPTEK > BATAN > Pusat Teknologi dan Keselamatan Reaktor Nuklir
Depositing User: Administrator Repository
Date Deposited: 14 May 2018 08:50
Last Modified: 31 May 2022 04:44
URI: https://karya.brin.go.id/id/eprint/1553

Actions (login required)

View Item
View Item