Upgrade Sistem Detektor PCD Ke SDD Pada Alat XRF Quant’X IRM

Fauzi Rahmatullah, Helmi and Jamaludin, Agus (2017) Upgrade Sistem Detektor PCD Ke SDD Pada Alat XRF Quant’X IRM. PIN, 10 (18). pp. 23-31. ISSN 1979-2409

[thumbnail of Upgrade Sistem Detektor PCD Ke SDD Pada Alat XRF Quant’X IRM] Text (Upgrade Sistem Detektor PCD Ke SDD Pada Alat XRF Quant’X IRM)
3688

Download (18kB)

Abstract

ABSTRAK

Kemajuan teknologi pendeteksi hasil sinar X - Ray fluoresence semakin berkembang, adanya teknologi elektronik semikonduktor membuat sistem pendeteksian semakin ramping dan simpel. Penggantian bagian detektor alat XRF Arl – quant’X bertujuan untuk memperbaiki sekaligus meningkatkan kemampuan alat tersebut di instalasi radiometalurgi- PTBBN. Peningkatan performa X –ray fluorescence dengan meng – upgrade dari PCD (Peltier Cooled Detector) ke SDD (Silicon Drift Detector) berhasil dibuktikan dengan data kalibrasi gain DAC yang sesuai pengaturan (setting), Uji kestabilan operasi di perulangan 50 kali proses yang memenuhi kategori stabil (On Spec), nilai resolusi terbaik yang ditunjukkan oleh nilai Full Width at Half Maximum (FWHM) sebesar 158 KeV, dan hasil pengujian kualitatif dengan ketepatan identifikasi spektrum di setiap unsurnya (Zr, Sn, Cr & Ni) serta hasil pengujian kuantitatif komposisi unsur standard zirconium (Zr = 98 %, Sn = 1,4 % , Cr = 0,1% , Ni = 0,05 %) telah sesuai dengan sertifikat CRM JAEA yang menjadi acuannya.

Kata Kunci : Upgrade, X-ray Fluoresence, PCD detector, SDD detector

ABSTRACT

The progress of x-ray detection technology with fluorescence is growing up, the presence of semiconductor electronic technology makes detection system more slim and simple. The replacement of XRF Arl-quant'X detector section aimed at fixing and improving the equipment at the radiometallurgi installation – PTBBN. Improved performance of X -ray fluorescence by upgrading from PCD (Peltier Cooled Detector) to SDD (Silicon Drift Detector) has been proven with calibration data of adjustable DAC gain setting, he stability test operation in 50 repetitions of the process that meets the stable category (On Spec), the best resolution value shown by the value of Full Width at Half Maximum (FWHM) of 158 KeV, and the results of qualitative testing with the accuracy of spectrum identification in each element (Zr, Sn, Cr & Ni) and the result of quantitative testing of standard zirconium element composition (Zr = 98%, Sn = 1,4%, Cr = 0,1%, Ni = 0,05%) are in accordance with JAEA CRM certificate which become its reference .

Keywords : Upgrade, X-ray Fluoresence, PCD detector, SDD detector.

Item Type: Article
Subjects: Taksonomi BATAN > Daur Bahan Bakar Nuklir dan Bahan Maju > Bahan Bakar Nuklir > Teknik Sintesis Bahan Bakar Nuklir
Taksonomi BATAN > Daur Bahan Bakar Nuklir dan Bahan Maju > Bahan Bakar Nuklir > Teknik Sintesis Bahan Bakar Nuklir
Divisions: BATAN > Pusat Teknologi Bahan Bakar Nuklir
IPTEK > BATAN > Pusat Teknologi Bahan Bakar Nuklir
Depositing User: Administrator Repository
Date Deposited: 17 May 2018 02:51
Last Modified: 31 May 2022 04:34
URI: https://karya.brin.go.id/id/eprint/1356

Actions (login required)

View Item
View Item