Yoyok Dwi Setyo, YDS and Muhammad Subekti, MS and Sujarwono, Sujarwono and Ranji Gusman, RG (2019) MONITORING DAN PENGUKURAN WAKTU RESPON DETEKTOR NEUTRON PADA RSG-GAS (Yoyok Dwi Setyo Pambudi 1, Muhammad Subekti 1, Sujarwono2, Ranji Gusman2). In: Seminar SENTEN PADANG Sumater Barat, 18 September 2019, Universitas ANDALAS Fakultas Teknik Padang Sumatera Barat.

Full text not available from this repository.

Abstract

ABSTRAK
MONITORING DAN PENGUKURAN WAKTU RESPON PADA DETEKTOR NEUTRON
REAKTOR GA SIWABESSY. Keselamatan adalah kondisi yang harus selalu tercapai dalam
pengelolaan sebuah reaktor nuklir dari saat pembangunan, pengoperasian hingga selesai
proses dekomisioning. Hingga saat ini dengan beroperasi selama lebih dari 30 tahun,
Reaktor Serba Guna - G.A. Siwabessy mengalami penuaan pada sistem dan struktur dan
komponennya. Penelitian ini membahas tentang penuaan pada sistem SIK, terutama sensor
neutron. Hasil yang diperoleh berupa waktu espon kanal sensor neutron berkisar 67,23 ms
pada untuk JKT 03 CX811, hingga terbesar 81,13 ms pada JKT 03 CX821. Nilai ini
menunjukkan bahwa dengan detektor netron tersebut tersebut berada pada kondisi yang
baik, dan memenuhi kriteria keselamatan. Selain itu ditunjukkan hasil monitoring empat buah
detektor neutron dan verifikasi dengan detektor daya.
Kata kunci: waktu respon, online monitoring, penuaan reaktor
ABSTRACT
MONITORING AND TIME RESPONSE MEASUREMENT OF GA SIWABESSY NEUTRON
DETECTOR. Safety is a condition that must always be maintained in the management of
nuclear reactors. Until now with operations for more than 30 years, the Reactor - G.A.
Siwabessy experienced aging in the system and its structure and components. This study
discusses the aging pheonmena in neutron detector of the reactor. The results obtained in
the form of a neutron sensor channel espon time range from 67.23 ms for JKT 03 CX811, to
the largest of 81.13 ms at JKT 03 CX821. This value indicates that the neutron detector is in
good condition, and meets the safety criteria. The results of four neutron detectors and
power detector monitoring were also performed.
Keyword: response time, online monitoring, reactor aging

Item Type: Conference or Workshop Item (Paper)
Subjects: Taksonomi BATAN > Keselamatan dan Keamanan Nuklir
Taksonomi BATAN > Keselamatan dan Keamanan Nuklir
Divisions: BATAN > Pusat Teknologi dan Keselamatan Reaktor Nuklir
IPTEK > BATAN > Pusat Teknologi dan Keselamatan Reaktor Nuklir
Depositing User: Iskandar Alisyahbana Adnan
Date Deposited: 07 Jul 2020 06:22
Last Modified: 30 May 2022 08:40
URI: https://karya.brin.go.id/id/eprint/9874

Actions (login required)

View Item
View Item