Mulya Juarsa, MJ and Joko Prasetio W, JPW and Edy Sumarno, ES and Kiswanta, KW and Ismu Wahyono, Puradwi (2005) PENGEMBANGAN BAGIAN UJI QUEEN GUNA PENELITIAN PERPINDAHAN PANAS SELAMA POST-LOCA : DESAIN DAN KONSTRUKSI AWAL (Mulya Juarsa, Joko P.W., Edy S., Kiswanta, Ismu H.). In: Prosiding Presentasi Ilmiah Teknologi Keselamatan Nuklir X ISSN No. 1410-0533, Pusat Teknologi dan Keselamatan Reaktor Nuklir.
Full text not available from this repository.Abstract
ABSTRAK
PENGEMBANGAN BAGIAN UJI QUEEN GUNA PENELITIAN PERPINDAHAN PANAS SELAMA POST-LOCA : DESAIN DAN KONSTRUKSI AWAL . Telah dilakukan pemahaman pada karakterisitik bagian uji QUEEN-I melalui hasil-hasil eksperimen mengenai rewetting yang telah dilakukan selama kurun waktu 2001-2004 dengan pencapaian temperatur awal dari batang pemanas pada bagian uji QUEEN-I hanya bisa mencapai temperatur awal maksimal sekitar 600oC. Sehingga hasil kalkulasi fluks kalor belum memadai untuk analisis perpindahan panasnya, terutama harga fluks kalor pada temperatur awal sekitar 800oC-930oC. Untuk memperjelas pemahaman fenomena perpindahan panas pendidihan selama Post-LOCA melalui peristiwa pendingin secara bottom reflooding pada temperatur awal yang tinggi, maka pada tahun 2004 telah dilakukan perancangan bagian uji yang baru (disebut QUEEN-II) dengan hasil desain baru yang dibuat untuk mampu memanaskan batang pemanas yang berupa tube SS diameter 3/8 inci hingga mendekati 930oC (pendinginan teras khusus untuk jenis PWR dengan temperatur maksimal cladding sekitar 930oC). Selain perancangan, konstruksi awal telah dilakukan dengan membuat prototipe alat pemanas berupa semi-silinder keramik yang dipasangi open coil heater untuk memanaskan batang pemanas secara radiasi. Diperoleh hasil pengujian awal untuk alat pemanas berupa korelasi polinomial orde 2 hasil regresi untuk kenaikan temperatur terhadap waktu.
Kata kunci: Fluks kalor, rewetting, reflooding
ABSTRACT
QUEEN TEST SECTION DEVELOPMENT FOR HEAT TRANSFER RESEARCH DURING POST-LOCA: DESIGN AND PRIMARILY CONSTRUCTION. The characteristic of QUEEN-I test section from the results of rewetting experiment during year 2001-2004 has been understood. But, the maximum initial temperatur for heated tube surface in QUEEN-I is only around 600oC. It was not enough to analyze heat transfer on high initial temperature around 800oC-930o C. In year 2004, the design of new test section have been conducted (named by QUEEN-II) in order to understand the boiling heat transfer phenomenon during Post-LOCA in which cooling process by mean of the bottom reflooding for high initial temperature occure in core cooling process for PWR type (with cladding maximal temperature reach 930oC). The heated tube (rod) is made from Stainless Steel tube with diameter size 3/8 inch. Heater device also was fabricated in 2004 in semi-cylindrical ceramic and open-coil heater to heat up rod by radiation. Initial test was conducted and the test data regresion resulted in orde 2 polynomial correlation for rod temperature increasing versus time.
Key Words: Heat Flux, rewetting, reflooding
Item Type: | Conference or Workshop Item (Paper) |
---|---|
Subjects: | Taksonomi BATAN > Keselamatan dan Keamanan Nuklir Taksonomi BATAN > Keselamatan dan Keamanan Nuklir |
Divisions: | BATAN > Pusat Teknologi dan Keselamatan Reaktor Nuklir IPTEK > BATAN > Pusat Teknologi dan Keselamatan Reaktor Nuklir |
Depositing User: | Administrator Repository |
Date Deposited: | 11 May 2020 05:54 |
Last Modified: | 31 May 2022 03:46 |
URI: | https://karya.brin.go.id/id/eprint/9841 |