EVALUASI PENERAPAN ENERGI DISPERSIVE X-RAY FLUORESCENCE (ED-XRF) UNTUK ANALISIS COAL FLY ASH

Syahfitri, Woro Yatu Niken and Kurniawati, Syukria and Adventini, Natalia and Lestiani, Diah Dwiana (2013) EVALUASI PENERAPAN ENERGI DISPERSIVE X-RAY FLUORESCENCE (ED-XRF) UNTUK ANALISIS COAL FLY ASH. In: Seminar Nasional Sains dan Teknologi Nuklir 2013, Bandung, Indonesia.

[thumbnail of 09_KK_39_Woro YNS_ptnbr_272-277.pdf]
Preview
Text
09_KK_39_Woro YNS_ptnbr_272-277.pdf

Download (277kB) | Preview

Abstract

EVALUASI PENERAPAN ENERGI DISPERSIVE X-RAY FLUORESCENCE (ED-XRF) UNTUK ANALISIS COAL FLY ASH. Energi Dispersive X-Ray Fluorescence (ED-XRF) merupakan salah satu teknik analisis nuklir untuk analisis unsur berbagai matriks cuplikan, salah satunya matriks lingkungan seperti coal fly ash (CFA). Untuk menjamin kualitas metode ED-XRF pada pengujian CFA, maka dilakukan evaluasi penerapan metode menggunakan SRM NIST 1633b Coal Fly Ash. Parameter evaluasi yang dilakukan, meliputi pengujian akurasi, presisi dan limit deteksi yang dilakukan terhadap 16 unsur (Al, Si, S, K, Ca, Ti, V , Cr, Mn, Fe, Ni, Cu, Zn, As, Cr dan Ba) yang terdapat pada CFA. Hasil pengujian ED-XRF, memberikan kesesuaian yang baik dengan nilai sertifikat. Nilai akurasi sebesar 96,1%-101,7% dan nilai presisi untuk repeatability dan reproducibility masing-masing sebesar 0,073,85% dan 0,70-4,53%, sedangkan batas deteksi dari XRF berkisar antara 0,8 hingga 100 ppm. Hasil analisis menunjukkan bahwa evaluasi penerapan ED-XRF pada analisis CFA memberikan nilai akurasi dan presisi yang baik dengan stabilitas jangka panjang dan batas deteksi minimum, sehingga metode ini dapat dipercaya untuk karakterisasi cuplikan CFA atau cuplikan serupa CFA dalam mendukung monitoring pencemaran lingkungan. ;

EVALUATION OF ENERGY DISPERSIVE X-RAY FLUORESCENCE (ED-XRF) APPLICATION FOR COAL FLY ASH ANALYSIS. Energy Dispersive X-Ray Fluorescence (ED-XRF) is one of nuclear analytical techniques for elemental analysis in various sample matrices, one of them is environmental matrices such as coal fly ash (CFA). To ensure the quality of the ED-XRF method in CFA analysis,evaluation of method applicability was conducted using NIST SRM 1633b Coal Fly Ash. Evaluation parameters testing including accuracy, precision and detection limits were perform for 16 elements (Al, Si, S, K, Ca, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, As, Cr, and Ba) in the CFA. The test results of XRF application, giving good agreement with the certificate value. Accuracy value range between 96.1%-101.7%, and precision value for repeatability and reproducibility are 0.07-3.85% and 0.704.53%, respectively, while the limit of detection of XRF ranged from 0.8 to 100 ppm. The analysis results showed that the application of XRF in CFA analyzes give good accuracy and precision with long-term stability and minimum detection limit, therefore this method is reliable for the characterization of the CFA samples or similar CFA samples in supporting environmental pollution monitoring.

Item Type: Conference or Workshop Item (Paper)
Uncontrolled Keywords: ED-XRF, akurasi, presisi dan coal fly ash
Subjects: Taksonomi BATAN > Isotop dan Radiasi
Taksonomi BATAN > Isotop dan Radiasi > Pemanfaatan Isotop dan Radiasi > Bidang SDA/Lingkungan
Taksonomi BATAN > Reaktor Nuklir > Pemanfaatan Reaktor > Teknologi Berkas Neutron
Taksonomi BATAN > Reaktor Nuklir > Pemanfaatan Reaktor > Teknologi Berkas Neutron
Taksonomi BATAN > Keselamatan dan Keamanan Nuklir > Keselamatan Lingkungan > Analisis Mengenai Dampak Lingkungan
Taksonomi BATAN > Keselamatan dan Keamanan Nuklir > Keselamatan Lingkungan > Analisis Mengenai Dampak Lingkungan
Divisions: BATAN > Pusat Sains dan Teknologi Nuklir Terapan
IPTEK > BATAN > Pusat Sains dan Teknologi Nuklir Terapan
Depositing User: Administrator Repository
Date Deposited: 03 Mar 2019 14:45
Last Modified: 31 May 2022 09:16
URI: https://karya.brin.go.id/id/eprint/8757

Actions (login required)

View Item
View Item