TH Rina M, THRM and Sri Wardani, SW and Sunarko, Sunarko (2002) EVALUASI AKURASI LAB. AAN P2TRR DENGAN ANALISIS CUPLIKAN STANDAR ACUAN BAHAN MAKANAN. In: PROSIDING SEMINAR HASIL PENELITIAN P2TRR, PRSG - BATAN.
Th. Rina.pdf
Download (277kB) | Preview
Abstract
EVALUASI AKURASI LAB. AAN P2TRR DENGAN ANALISIS CUPLIKAN STANDAR ACUAN BAHAN MAKANAN. Metode AAN adalah suatu metode analisis yang memiliki tingkat presisi dan akurasi yang tinggi. Untuk itu telah dilakukan evaluasi presisi dan akurasi Lab. AAN P2TRR dengan menggunakan bahan acuan bersertifikat SRM 1573a Tomato Leaf dan CRM No.9 Sargasso. Iradiasi dilakukan di system rabit RSG-GAS dan pencacahan dilakukan dengan spectrometer gamma. Hasil analisis menunjukkan bahwa untuk SRM 1573a dari 40 unsur tersertifikasi, 17 unsur dapat dianalisis secara kualitatif dan pada CRM No.9 dari 30 unsur tersertifikasi, 16 unsur dapat dianalisis secara kualitatif. Hasil analisis kuantitatif pada kedua jenis sample tersebut memberikan hasil persen penyimpangan bervariasi tiap unsur antara 2 – 10,5 %. Nilai penyimpangan ini masih dibawah 15 %, ini menunjukkan bahwa presisi dan akurasi Lab. AAN P2TRR cukup baik.
Kata Kunci : Akurasi, bahan acuan standar.
ABSTRACT
THE EVALUTION OF ACCURATION OF NAA METHOD USED BY P2TRR LABORATORY WITH FOOD STANDARD REFERENCE MATERIAL ANALYSIS. The NAA method is the analysis method with high precision and accuration level. The precision and accuration of NAA laboratory in P2TRR had been evaluated with SRM 1573a Tomato Leaf and CRM No.9 Sargasso. Samples were irradiated in RSG-GAS’s rabbit system and counted with gamma spectrometry. The results obtained from this research are for the SRM 1573a sample the test could analize 17 elements of the 40 certified elements, and for CRM No.9 sample the test could analize 16 elements of the 30 certified elements. The result of quantitative analysis indicate the different deviation of each element between 2 – 10,5 % compared to the certificate data. This deviation value <15%, this value shows that the precision and accuration level is good enough.
Key words : Accuration, Standard reference material
Item Type: | Conference or Workshop Item (Paper) |
---|---|
Subjects: | Taksonomi BATAN > Reaktor Nuklir > Pemanfaatan Reaktor > Eksperimen Reaktor Taksonomi BATAN > Reaktor Nuklir > Pemanfaatan Reaktor > Eksperimen Reaktor |
Divisions: | BATAN > Pusat Reaktor Serba Guna IPTEK > BATAN > Pusat Reaktor Serba Guna |
Depositing User: | Administrator Repository |
Date Deposited: | 11 Feb 2019 03:24 |
Last Modified: | 31 May 2022 03:55 |
URI: | https://karya.brin.go.id/id/eprint/8599 |