PENGKAJIAN PERBAIKAN FAKTOR DAYA SISTEM KELISTRlKAN RSG-GAS

Yan Bony Marsahala, YBM (1999) PENGKAJIAN PERBAIKAN FAKTOR DAYA SISTEM KELISTRlKAN RSG-GAS. PROSIDING SEMINAR HASIL PENELITIAN PRSG. ISSN 0854-5278

[thumbnail of Yan Bony M.pdf]
Preview
Text
Yan Bony M.pdf

Download (5MB) | Preview

Abstract

PENGKAJIAN PERBAIKAN FAKTOR DAYA SISTEM KELISTRIKAN RSG-GAs. Rencana kenaikan tarif listrik oleh PLN perlu ditanggapi secara serius dalam rangka berpartisipasi pacta gerakan efisiensi nasional. Untuk itu perlu mengkaji dampak kenaikan tarif terhadap pemakaian enersi listrik oleh PRSG. Kajian dimaksud akan dilakukan dari sisi teknis dan sisi ekonomi. Mengingat bahwa faktor daya merupakan salah satu parameter yang berperan menentukan tingkat etisiensi, maka dengan asumsi faktor daya dapat diperbaiki menjadi 0.95, akan diperoleh efisiensi tertinggi teknis. Pada tingkat efisiensi ini, maka jumlah rupiah yang dibayar oleh PRSG setiap bulan akan berkurang, walaupun beban yang digunakan tetap. Tingkat efisiensi tertinggi tersebut, dapat dicapai dengan pemasangan "capacitor bank" secara paralel dengan sumter daya pacta titik titik tertentu. Tinjauan dari sisi ekonomi, dilakukan dengan investasi pemasangan capacitor bank berikut biaya instalasinya, dan pengurangan alas biaya rekening listrik. Selisih biaya rekening listrik"tanpa pemasangan capasitor bank" terhadap biaya "dengan pemasangan capasitor bank" akan dibandingkan dengan total rupiah yang diperlukan untuk pembelian/instalasi/capasitor bank. Apabila selisih biaya tersebut bernilai positip maka rencana pemasangan capasitor bank dapat dipertimbangkan, namun hila harga tersebut mempunyai nilai negatip, maka rencana perbaikan faktor daya dimaksud dapat diabaikan. Dari hasil perhitungan diperoleh bahwa selisih biaya dimaksud di alas bernilai positip, dengan demikian kajian perbaikan factor daya dapat dipertimbangkan untuk ditindak lanjuti.
ABSTARCT INVESTIGATION OF INCREASING OF RSG-GAS ELECTRICAL SYSTEM POWER FACTOR The plan of increasing electric bill by PLN need response in seriously in order to participated in national efficiencies. So, it necessary to investigate the effect of increasing electric bill against electric energy used by PRSG. The investigation will be done in technical side, and economic side. Remember that power factor is one of parameter that influence the rate of efficiencies, so that by assumption that the power factor can be drawn up to 0.95 will give the higher technical efficiency. At these efficiencies, the amount of rupiah paid by PRSG at every month, will decrease although use the same load. The efficiency rate at that higher level can be reach by installed capacitor bank in parallel to power source at appropriate points. The review in economic aspect will be done by calculate capitals of capacitor bank include installation cost, and the decreasing of electric bill. The comparison value of electric bill without capacitor bank to the cost of capacitor bank installation will be compare to the total cost of buying and installation of capacitor bank. If the comparison have the positive value, so the plan of increasing of power factor could be comparing to be done, but if it have the negative value, so it can be denied. By calculation results we find that the comparison have the positive value, so that the increasing of power factor could be compare to be done.

Item Type: Article
Subjects: Taksonomi BATAN > Reaktor Nuklir > Pemanfaatan Reaktor > Pembangkitan Listrik Reaktor Daya
Taksonomi BATAN > Reaktor Nuklir > Pemanfaatan Reaktor > Pembangkitan Listrik Reaktor Daya
Divisions: BATAN > Pusat Reaktor Serba Guna
IPTEK > BATAN > Pusat Reaktor Serba Guna
Depositing User: Administrator Repository
Date Deposited: 21 Sep 2018 03:00
Last Modified: 02 Jun 2022 02:44
URI: https://karya.brin.go.id/id/eprint/4009

Actions (login required)

View Item
View Item